6.10.3
Requirement
6.10.4
Requirement
Cleaning the cooking zone automatically with WaveClean
Confirm
d) Tap the
button.
Select cleaning level
⇨ The
e) Tap the "START STOPP" button.
⇨ If necessary, the cooling zone cools until the cleaning temperature of
60 °C is reached.

Inserting the cleaning cartridge

SAFETY INSTRUCTIONS
Use only cleaning cartridges with an undamaged wax seal.
If the wax seal is damaged, the cleaner can enter the cleaning circuit
prematurely or not dissolve completely, so that complete cleaning is no
longer assured.
Insert the cleaning cartridges only when requested to do so.
➢ Cleaning cartridges sealed and undamaged
a) Open cooking zone door.
b) Remove the cover from the cartridge.
Inserting a cartridge
c) Place the cartridge into the holder on the air diverter or into the holder on
the tray trolley.
SAFETY INSTRUCTIONS
Never operate the unit in the automatic cleaning mode without a cleaning
cartridge.
a) Close the cooking zone door.

Starting automatic cleaning

➢ Water connection is opened
➢ The unit is on
➢ Cleaning level selected
➢ Cooking zone temperature at 60°C (140°F)
a) Tap the "START STOPP" button.
Cleaning and caring for the unit
window is displayed.
6