H. Correct Baffl e & Blanket Placement
WARNING
Fire Risk
Firebox damage due to improper baffl e place-
ment is not covered by warranty. Operate the
wood burning appliance with the baffl e in the
correct position only.
Not doing so could result in:
• Reduced effi ciency
• Overheating the chimney
• Overheating the rear of the fi rebox
• Poor performance
Ensure correct baffl e placement and replace baffl e com-
ponents if damaged or missing.
The baffl e boards are FRAGILE. Use extreme caution when
loading fi rewood to prevent:
• Cracking, breaking or damaging the baffl e boards
DO NOT operate the stove without baffl e boards
CORRECT POSITION
Ceramic Blanket
Baffle Board
Ceramic Blanket and Baffl e Board MUST
be in contact with the back of the fi re-
box and even with each other in the front.
Figure 29.1
September 1, 2010
CAUTION
Back of Firebox
INCORRECT POSITIONS
Ceramic Blanket and Baffl e Board are NOT in
contact with the back of the fi rebox.
Ceramic Blanket is NOT in contact with the
back of the fi rebox and NOT even with the Baf-
fl e Board in the front.
Ceramic Blanket
Baffle Board
Ceramic Blanket is bunched up at the back of
the fi rebox and NOT even with the Baffl e Board
in the front.
Figure 29.2
7033-277H