Remove the SFF hot-plug drive cage.
7.
To replace the component, reverse the removal procedure.
4-bay and 8-bay LFF non-hot-plug drive cable
assemblies
WARNING:
internal system components to cool before touching them.
CAUTION:
precautions before beginning any installation, removal, or replacement procedure. Improper
grounding can cause electrostatic discharge.
To remove the component:
Power down the server (on page 26).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Remove all drives
3.
page 34).
Do one of the following:
4.
Extend the server from the rack (on page 26).
o
Remove the server from the rack (on page 29).
o
Remove the access panel
5.
If an expansion board is installed in the primary PCI riser cage, then remove the PCI riser cage
6.
("Remove the PCI riser
Remove the air baffle (on page 31).
7.
To reduce the risk of personal injury from hot surfaces, allow the drives and the
To prevent damage to electrical components, take the appropriate anti-static
("Non-hot-plug
drive" on page 34) and drive carriers
("Access
panel" on page 37).
cages" on page 29).
("Non-hot-plug drive
Removal and replacement procedures 39