Enabling The Dedicated Ilo Management Module - HP ProLiant DL180 Gen9 Service Manual

Hide thumbs Also See for ProLiant DL180 Gen9:
Table of Contents

Advertisement

WARNING:
internal system components to cool before touching them.
CAUTION:
precautions before beginning any installation, removal, or replacement procedure. Improper
grounding can cause electrostatic discharge.
To remove the component:
Power down the server (on page 26).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Do one of the following:
3.
Extend the server from the rack (on page 26).
o
Remove the server from the rack (on page 29).
o
Remove the access panel
4.
If an expansion board is installed in the primary PCI riser cage, then remove the PCI riser cage
5.
("Remove the PCI riser
Remove the dedicated iLO management module.
6.
To replace the component, reverse the removal procedure. After installing the new dedicated iLO
management module, enable the dedicated iLO connector
module" on page 65).

Enabling the dedicated iLO management module

The onboard NIC 1/shared iLO connector is set as the default system iLO connector. To enable the
dedicated iLO management module, use the iLO 4 Configuration Utility accessible within the HP UEFI System
Utilities.
To reduce the risk of personal injury from hot surfaces, allow the drives and the
To prevent damage to electrical components, take the appropriate anti-static
("Access
panel" on page 37).
cages" on page 29).
("Enabling the dedicated iLO management
Removal and replacement procedures 65