Models 07266Tc And 07279; Models 07273 And 07273Tc - Toro Workman MD Operator's Manual

Hide thumbs Also See for Workman MD:
Table of Contents

Advertisement

If major repairs are ever needed or assistance is required,
contact an Authorized Toro Distributor.
To be sure of optimum performance and safety, always
purchase genuine Toro replacement parts and accessories.
Replacement parts and accessories made by other
manufacturers could be dangerous. Altering this machine
in any manner may affect the operation, performance,
durability of the machine, or its use may result in injury
or death. Such use could void the product warranty of
The Toro® Company.
This machine should not be modified without
authorization from The Toro® Company. Direct any
inquiries to The Toro® Company, Commercial Division,
Vehicle Engineering Dept., 8111 Lyndale Ave. So.,
Bloomington, Minnesota 55420–1196 USA.

Models 07266TC and 07279

Sound Power
This unit has a guaranteed sound power level of 96 dBA,
which includes an Uncertainty Value (K) of 1 dBA.
Sound power level was determined according to the
procedures outlined in EN ISO 11094.
Sound Pressure
This unit has a sound pressure level at the operator's ear of 83
dBA, which includes an Uncertainty Value (K) of 1 dBA.
Sound pressure level was determined according to the
procedures outlined in EN ISO 11201.
Hand-Arm Vibration
Measured vibration level for right hand = 1.5 m/s
Measured vibration level for left hand = 1.03 m/s
Uncertainty Value (K) = 0.5 m/s
Measured values were determined according to the procedures
outlined in EN 1032.
Whole Body Vibration
Measured vibration level = 0.42 m/s
Uncertainty Value (K) = 0.5 m/s
Measured values were determined according to the procedures
outlined in EN 1032.
2
2
2
2
2

Models 07273 and 07273TC

Sound Power
This unit has a guaranteed sound power level of 96 dBA,
which includes an Uncertainty Value (K) of 1 dBA.
Sound power level was determined according to the
procedures outlined in EN ISO 11094.
Sound Pressure
This unit has a sound pressure level at the operator's ear of 86
dBA, which includes an Uncertainty Value (K) of 1 dBA.
Sound pressure level was determined according to the
procedures outlined in EN ISO 11201.
Hand-Arm Vibration
Measured vibration level for right hand = 1.5 m/s
Measured vibration level for left hand = 1.06 m/s
Uncertainty Value (K) = 0.5 m/s
Measured values were determined according to the procedures
outlined in EN 1032.
Whole Body Vibration
Measured vibration level = 0.35 m/s
Uncertainty Value (K) = 0.5 m/s
Measured values were determined according to the procedures
outlined in EN 1032.