Setup Page Elements (Cont.)
Display/Panel Timeout: Sets the length of time the panel can remain idle before activating the sleep mode. When the
Inactivity Page Flip
Timeout:
Panel Brightness:

Panel Information Page

The Panel Information page (FIG. 102) centers around Modero panel properties such as the resolution used, on-board
memory, firmware, address/channel information, and string information.
FIG. 102
Panel Information page (takes its' information from the touch panel)
The elements of the Panel Information page are described in the table below:
Panel Information Page Elements
Back:
Connection Status icon: This visual display of the connection status allows the user to have a current visual update of
Panel Type:
Firmware Version:
Setup Port:
High Port:
High Address:
High Channel:
VG Series Modero Touch Panels
device goes into sleep mode, the LCD is powered-down.
• Press the UP/DN buttons to increase/decrease the time until the panel
times out. Range = 0 - 240 minutes.
• Use this button to set the timeout value to zero and disable the sleep mode.
• Note: Display timeout values affect battery performance. Small timeout values increase
the life of the battery charge. Greater timeout values may require more frequent battery
charging.
Sets the number of minutes of inactivity before the panel automatically flips to a pre-selected
touch panel page. When the device goes into this inactivity mode, the LCD does not power-
down.
• Press the UP/DN buttons to increase/decrease the time the panel can remain inactive
before it flips to the preset page. Range = 0 - 240 minutes.
• Use this button to set the timeout value to zero and disable the inactivity page flip mode.
• The touch panel page used for the Inactivity page flip is shown within a small Inactivity
Page field.
Sets the display brightness level of the panel.
• Press the UP/DN buttons to adjust the brightness level. Range = 0 - 100.
• The on-screen bargraph can be dragged to adjust the Brightness level which is then
reflected as a corresponding numeric value within the Panel Brightness field.
Returns you to the previously active touch panel page.
the panel's connection status regardless of what page is currently active.
• A Lock only appears on the icon if the panel has established a connection with a currently
secured target Master (requiring a username and password).
Displays the model of the Modero panel being used.
Displays the G4 firmware version being used by the panel.
• Verify you have the latest version from www.amx.com.
Displays the setup port information/value being used by the panel.
Displays the high port (port count) value for the panel.
Displays the high address (address count) value for the panel.
Displays the high channel (channel count) value for the panel.