Ccd Unit Position Adjustment - Konica Minolta 7115 Service Manual

Hide thumbs Also See for 7115:
Table of Contents

Advertisement

(2)

CCD Unit Position Adjustment

NOTE
• This adjustment is made when the CCD Unit has been replaced.
<Adjustment Procedure>
1. Place a scale on the Original Glass in parallel with the Original Width Scale and make a
copy.
Right
Left
4022D017AB
2. Measure the length of the scale on the copy.
Requirement
• In compliance with "Scanner CD Zoom Adjust-
ment."
D-59
If the measured value falls outside the specified
range, perform the following step to make an
adjustment.
3. Loosen three CCD Unit mounting screws, slide
the CCD Unit to the right or left, and secure it in
position.
Adjustment Instructions
If the length on the copy is longer than the actual
one, move the CCD Unit to the right.
If the length on the copy is shorter than the actual
one, move the CCD Unit to the left.
If a single adjustment procedure does not success-
fully bring the amount of error into the specified
range, repeat the steps.
D-65

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7118

Table of Contents