Install the Horizontal Termination Cap
Vent termination must not be recessed in the wall. Siding
may be brought to the edge of the cap base.
Flash and seal as appropriate for siding material at outside
edges of cap
When installing a horizontal termination cap, follow the cap
location guidelines as prescribed by current ANSI Z223.1
and CAN/CGA-B149 installation codes.
Designer
Series
Top vented Designer units require a DVP12 be added after the elbow.
DVP-TRAP1 can adjust 1-7/8 in. (4-3/16 to 6-1/16)
DVP-TRAP2 can adjust 4 in. (6-9/16 to 10-9/16)
DVP-HPC1 can adjust 2-1/8 in. (4-1/4 to 6-3/8)
DVP-HPC2 can adjust 4-1/8 in. (6-3/8 to 10-1/2)
Figure 8.12 Venting through the Wall
34
Heat Shield or
Wall Shield
Firestop
Vent depth from back of appliance to
outside surface of exterior wall
(see chart below)
Cap Specifi cation Chart (depth without using additional pipe sections)
DVP-TRAPK1
Top Vent Depth
4 to 5-7/8 in.
DVP-HPC1
Top Vent Depth
4-1/8 to 6-1/4 in.
Note: Where required, an exterior wall fl ashing is available.
When penetrating a brick wall, a brick extension kit is
available for framing the brick.
Heatilator • Caliber Multi-Sided Direct Vent • 4002-079 Rev K • 11/07
Extended
Heat Shield
Slip Section
can be extended
INTERIOR
DVP-TRAP1
DVP-TRAPK2
Rear Vent Depth
Top Vent Depth
5-3/4 to 7-5/8 in.
6-3/8 to 10-3/8 in.
DVP-HPC1
DVP-HPC2
Rear Vent Depth
Top Vent Depth
3-5/8 to 5-3/4 in.
6-1/4 to 10-3/8 in.
WARNING
Burn Risk
Local codes may require installation of a
cap shield to prevent anything or anyone
from touching the hot cap.
Heat Shield
1-1/2 in. (38 mm) min.
overlap
EXTERIOR
SHEATHING
DVP-TRAP2
Rear Vent Depth
8-1/8 to 12-1/8 in.
DVP-HPC2
Rear Vent Depth
5-3/4 to 9-7/8 in.