Top Vent—Horizontal Termination—Two or Three Elbows
You may use a maximum of three 90° elbows (or six 45° elbows) in any vent confi guration, Some may be installed hori-
zontally.
Figure 5.6
Two or Three Elbows, some Horizontal
Note: Subtract 3 ft (914 mm) from the total horizontal
measurement for each 90° elbow installed horizontally.
Subtract 1-1/2 ft (456 mm) from the total horizontal
measurement for each 45° elbow installed horizontally.
V
min.
V
max.
1
1
6 in./152 mm
-
12 in./305 mm
-
18 in./457 mm
-
24 in./810 mm
-
-
25 ft/7.62 m
H
Installed
Horizontally
H
H
2
2
Heatilator • Caliber Multi-Sided Direct Vent • 4002-079 Rev K • 11/07
Table 5.3
H
+ H
max. H
+ H
1
2
1
6 ft/1.83 m
11 ft/3.35 m
11 ft/3.35 m
18 ft/5.49 m
18 ft/5.49 m
25 ft/7.62 m
25 ft/7.62 m
25 ft/7.62 m
25 ft/7.62 m
3
+ H
max.
2
3
-
Installed
Vertically
H
1
V
1
17