7.7
To Reset The Filter Icon
•
Press the UP + LOCK button for 4 seconds to reset the Filter monitor.
Note: Do not reset the monitor before the filter is changed, or monitoring will be inaccurate.
7.8
To Disable The Filter Alarm (Measured Fill Products)
•
Disable the alarm if no filter is to be fitted.
•
Press and hold the MEASURED FILL button, and press and hold the MENU and UP
buttons for 4 seconds to turn this feature on/off.
7.9
Flowmeter Calibration/Measured Fill Calibration
(Measured Fill Products Only)
This calibration is to be carried out when the set quantities may be under or over the default
settings.
Example: Default setting is 250 mls/8fl ozs, however only 200 mls/7fl ozs is being dispensed.
•
Press and hold the MEASURED FILL button, then press the DOWN button to enter the
calibration mode.
•
100 CAL will be displayed in the MEASURED FILL window.
•
The 100 display is a percentage. It can be increased by using the UP button, or decreased
by using the DOWN button.
7.10
To Disable The Filter Alarm (Non-Measured Fill
Products)
Disable the alarm if no filter is to be fitted.
•
Press and hold the MENU + UP + LOCK buttons for 4 seconds to turn this feature on/off.