P52DF* Indoor Gas Fireplace
Notes Wall Mounted Terminations: 5"/10" Top & Rear Vent
■ All dimension lengths for vertical or horizontal runs
are measured from center of the vent pipe.
■ Venting runs must fall within the limits set by the
venting graphs, see Figure 12.
■ Fireplace must be converted to Rear Vent configuration
prior to running vent, see Figure 7 and 7a.
The Venting Graph
Measure the vertical height from the fireplace hearth to the
centre of the termination and the horizontal run from the
fireplace flue collar to the wall flange of the termination. Plot
on the Venting Graph Figure 12 with an 'X'.
If the 'X' falls on or above the top boundary of the shaded
area, the installation is acceptable.
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 120" and the
horizontal run to the wall flange of the vent termination is
138", this would be an acceptable installation.
Example B: (Unacceptable Installation)
If the vertical dimension from the hearth is 48" and the
horizontal run to the wall flange of the vent termination is
72", this would not be an acceptable installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is
60" and the horizontal run to the wall flange of the vent
termination is 144", this would not be an acceptable
installation.
Acceptable vent run
within non-shaded area.
B
56"
20 "
Figure 12. 5"/10" Top or Rear Vent Venting Graph for wall mounted
terminations.
Page 14
Installation
A
C
Unacceptable vent run
within shaded area.
If your installation does not fall
within the venting graph parame-
ters, please contact a local Montigo
Dealer for Power Venting options.
Flex section
Hearth
Figure 12a. 5"/10"Top Vented, wall mounted installation with one
90° bend. The vent run must comply with Venting Graph for Top
vent, wall mounted terminations, Figure 12
Flex or Rigid
Section
12"
Max.
Figure 12b. 5"/10" Rear Vented, wall mounted Multi-elbow
termination installation. The vent run must comply with the Venting
Graph for Rear vent, wall mounted terminations, Figure 12.
Note: If power venting, vent run must be reduced to 5"/8"
or 4"/7". contact your Montigo dealer to discuss power
venting options.
Note:
Images are shown without screens for clarity
purposes. However, your fireplace should not be operated
without proper installation of screens.
20" Max. for min Vertical
Heat Shield
Termination
56" Min.
Exterior
Wall
.
8" Max.
27"
Min.
56"
Min.
28 3/4"
XG0196 - 150204.3