Error Indications; Entrapment; Comm Link Connection Failure; Mgt Obstacle Transmitter Trouble - Linear VS-GSWG Installation Manual

Swing gate operator
Table of Contents

Advertisement

Error Indications

During abnormal operation, the Controller's displays and
beeper will indicate the error condition that has occurred.

Entrapment

If an entrapment condition occurs detected by two repeated
open or close obstruction triggers, the Controller will lock
the operator out. The beeper will sound constantly and the
gate will not operate. To reset the Controller press the STOP
button or press the RESET button on the operator's cover.
WARNING
The Stop and/or Reset button must be located in the line-of-
sight of the gate. Activation of the reset control shall not
cause the operator to start.

COMM LINK Connection Failure

In dual gate installations, if there is a connection failure
between the two operators, the COMM LINK indicator will
blink once a second. During this condition the gate will not
operate, except if triggered by the FIRE DEPT input, which
functions normally.

MGT Obstacle Transmitter Trouble

If any MGT transmitters are used with the operator, their
supervision feature will alert the Controller if there is any
trouble with the transmitter. MGT transmitters send hourly
status reports and will send low battery reports when the
transmitter has a low battery. The MGT transmitters also
have a tamper detection switch that will trigger when their
case is opened.
When the Controller detects a low transmitter battery, a
tamper signal, or missing transmitter status reports, the
gate will still operate normally, but the beeper will change
as follows:
• The Pre-start Alarm will beep twice as fast.
• The Run Alarm will beep twice as fast and continue for fi ve minutes
after the gate stops.
• The sounder will "chirp" every fi ve seconds when the gate is idle.
Correct the trouble (close case, replace battery, or replace
transmitter) to clear the obstacle transmitter trouble
indications.

Maximum Run Time Exceeded

If the Maximum Run Time is exceeded, the Controller stops
the operator the same as if a double obstacle has occurred
in an entrapment condition. The entrapment alarm sounds
constantly, and is cleared by pressing the STOP button or the
RESET button on the cover. After the STOP or RESET button
is pressed, because the Maximum Run Time has been
exceeded, the sounder will beep twice every fi ve seconds.
The next operation of the gate will clear the indication.
VS-GSWG Swing Gate Operator Installation Guide
CONTROLLER ERROR CAUSES AND INDICATIONS
ERROR CAUSE
TWO SAFETY REVERSALS (ON
SINGLE GATE OR ON EITHER
DUAL GATE)
MAXIMUM RUN TIMER
EXCEEDED ON OPENING
MAXIMUM RUN TIMER
EXCEEDED ON CLOSING
COMM LINK FAILURE
GATE FULL OPEN RESULTING
FROM FIRE DEPT INPUT
FAIL SAFE OR FAIL SECURE
BECAUSE OF BATTERY VOLTAGE
DROP BELOW 21.6 VDC DUE TO
AC POWER LOSS
OTHER CONTROLLER IN
ENTRAPMENT (DUAL GATE)
LOW AC VOLTAGE AT
CONTROLLER
INPUT TRIGGERED DURING
ENTRAPMENT LOCKOUT
COMPATIBILITY PROBLEM
EEPROM PROBLEM
DC MOTOR MISMATCH
MOTOR FAILURE
AC POWER LOSS IN OPEN OR
CLOSE IMMEDIATE POWER
FAIL MODE
MAXIMUM RUN TIMER
EXCEEDED AFTER AC POWER
LOSS
MGT SUPERVISORY CONDITION
(TAMPER, LOW BATTERY,
MISSING HOURLY STATUS)
- 23 -
ERROR INDICATION
HOW TO CLEAR
En 00, CONTINUOUS ALARM
PRESS STOP BUTTON
BEEPER, GATE DISABLED
PRESS STOP BUTTON,
En 01, AND MAX RUN LED,
CLEARS CONTINUOUS ALARM,
CONTINUOUS ALARM BEEPER,
THEN DOUBLE BEEP EVERY
GATE DISABLED
5 SECONDS UNTIL NEXT
OPERATION
PRESS STOP BUTTON,
En 02, AND MAX RUN LED,
CLEARS CONTINUOUS ALARM,
CONTINUOUS ALARM BEEPER,
THEN DOUBLE BEEP EVERY
GATE DISABLED
5 SECONDS UNTIL NEXT
OPERATION
En 03, AND COMM LINK LED,
CONTINUOUS ALARM BEEPER
PRESS STOP BUTTON, CLEARS
FOR 1 MINUTE, GATE DISABLED
CONTINUOUS ALARM
(EXCEPT FOR FIRE DEPT INPUT)
En 04, GATE DISABLED
PRESS STOP BUTTON
BATTERY VOLTAGE MUST RISE
En 05, GATE DISABLED
ABOVE 24 VDC
CLEAR ENTRAPMENT ON OTHER
En 06, GATE DISABLED
CONTROLLER (PRESS STOP)
RESTORE AC POWER TO
En 07, GATE DISABLED
NORMAL LEVEL
En 08, GATE DISABLED
PRESS STOP BUTTON
UPDATE FIRMWARE AND RESET
En 09, GATE DISABLED
BOTH PAIRED CONTROLLERS
En 10, GATE DISABLED
TRY RESET, CALL TECH. SUPPORT
REPROGRAM MOTOR TYPE OR
CHANGE DC MOTOR BOARD,
En 11, GATE DISABLED
NEXT GATE MOVEMENT WILL
RETRY DC MOTOR CHECK
En 12, GATE DISABLED
CALL TECH. SUPPORT
En 13
REAPPLY AC POWER
BATTERY VOLTAGE MUST RISE
En 14
ABOVE 24 VOLTS
FAST BEEPS DURING PRESTART,
CLEARS WHEN MGT CONDITION
FAST BEEP RUN ALARM, CHIRP
CLEARS
EVERY 5 SECONDS AT IDLE
P1250 Revision X6 7-8-2011

Advertisement

Table of Contents
loading

Table of Contents