Indicator Descriptions

INDICATOR DEFINITION
OPERATION
PROGRAMMING
24 VOLT INPUT
POWER
24 VOLT DC
ACCY POWER
OPEN
CLOSE
STOP
PROGRAM
REVERSE
DELAY SET
LOCKOUT
ALARM SET
RADIO
LEARN
OPEN CURRENT
SET
OPEN OBSTR
MGT 2 SET
OPEN RELAY
LH/RH SET
OPEN LIMIT
BRAKE DELAY
CLOSE CURRENT
SET
CLOSE OBSTR
MGT 1 SET
CLOSE RELAY
AUTO CLOSE SET
CLOSE LIMIT
AC DC SET
SINGLE
SET
MAX RUN
SET
COMM LINK
SET
MAINT ALERT
SET
LEFT OR RIGHT
"RL"
HAND OPERATION
SINGLE OR
"PM"
DUAL GATE
AUTO CLOSE
"AC"
TIMER
RUN ALARM
"RP"
PRE-START ALARM
MAXIMUM OPEN
"OC"
CURRENT
MAXIMUM CLOSE
"CC"
CURRENT
ADVANCED
"AD"
PROGRAMMING
VS-GSWG Swing Gate Operator Installation Guide
INDICATION WHEN LIT
DURING NORMAL OPERATION
LOW VOLTAGE AC POWER IS PRESENT
LOW VOLTAGE DC POWER IS PRESENT
OPEN SIGNAL PRESENT FROM THE INTERNAL
RECEIVER OR AN EXTERNAL DEVICE
CONNECTED TO THE OPEN INPUT TERMINAL
CLOSE SIGNAL IS PRESENT FROM A DEVICE
CONNECTED TO THE CLOSE INPUT TERMINAL
STOP INPUT TERMINAL IS OPEN AND
NOT CONNECTED TO COMMON
SIGNAL FROM REVERSING DEVICE IS PRESENT
CONTROLS AND OPERATOR ARE LOCKED OUT
BECAUSE OF EXISTING TROUBLE CONDITION
BUILT-IN RECEIVER IS DETECTING A RADIO
SIGNAL FROM A REMOTE CONTROL
MOTOR CURRENT HAS EXCEEDED THE
OPEN CURRENT SETTING WHILE OPENING
OPEN OBSTRUCTION TERMINAL CONNECTED
TO COMMON BY BEAM OR SAFETY EDGE, OR
SIGNAL FROM MGT OBSTACLE TRANSMITTER
OPEN RELAY IS ACTIVATED
OPEN LIMIT SWITCH IS ACTIVATED
MOTOR CURRENT HAS EXCEEDED THE
CLOSE CURRENT SETTING WHILE CLOSING
CLOSE OBSTRUCTION TERMINAL CONNECTED
TO COMMON BY BEAM OR SAFETY EDGE, OR
SIGNAL FROM MGT OBSTACLE TRANSMITTER
CLOSE RELAY IS ACTIVATED
CLOSE LIMIT SWITCH IS ACTIVATED
SINGLE TERMINAL CONNECTED TO COMMON
BY AN EXTERNAL PUSHBUTTON OR RADIO
MAXIMUM RUN TIMER HAS BEEN EXCEEDED
DUAL OPERATOR CONNECTION DETECTED,
BLINKS IF CONNECTION HAS FAILED
MAINTENANCE IS REQUIRED ON OPERATOR
APEX FUNCTION DISPLAY INDICATIONS
MAXIMUM
"RT"
RUN TIMER
SINGLE BUTTON
"SB"
INPUT SETUP
STAGGER
"SM"
MODE
STAGGER
"ST"
TIME
AUXILIARY
"AR"
RELAY MODE
REVERSE
"RD"
DELAY TIME
BRAKE
"BD"
DELAY TIME
- 9 -
INDICATION WHEN LIT
DURING PROGRAMMING
CONTROLLER IS IN PROGRAMMING MODE
SET REVERSE DELAY TIME
SET RUN ALARM AND PRE-START ALARM
TRANSMITTERS CAN BE ENTERED INTO
MEMORY (UP TO 40 TRANSMITTERS)
SET MAXIMUM OPEN CURRENT
SET MGT #2 FUNCTION
SET LEFT-HAND RIGHT-HAND OPERATION
SET MAXIMUM CLOSE CURRENT
SET MGT #1 FUNCTION
SET AUTO-CLOSE TIME
SET MOTOR TYPE
SET SINGLE BUTTON INPUT FUNCTION
SET MAXIMUM RUN TIME
SET MAINTENANCE ALERT CYCLE COUNT
CONSTANT
"CP"
PRESSURE MODE
SHADOW LOOP
"SP"
OPEN INHIBIT
RESET CYCLE
"CT"
COUNT
MAINTENANCE ALERT
"MA"
TRIGGER
MID-TRAVEL
"MT"
STOP POSITION
ANTI-TAILGATE
"AT"
ENABLE
RADIO
"RA"
ENABLE
LEARN
"TL"
TRANSMITTERS
DELETE
"TD"
TRANSMITTERS
LEARN MGT
"ML"
TRANSMITTERS
ERASE MGT
"MD"
TRANSMITTERS
MOTOR TYPE
"MO"
SELECTION
RESET TO
"CL"
FACTORY DEFAULTS
P1250 Revision X6 7-8-2011