Error Indications

During abnormal operation, the Controller's displays and beeper will
indicate the error condition that has occurred.
Entrapment
If an entrapment condition occurs detected by two repeated open or
close obstruction triggers, the Controller will lock the operator out. The
beeper will sound constantly and the gate will not operate. To reset the
Controller press the STOP button or press the RESET button on the
operator's cover.
WARNING
The Stop and/or Reset button must be located in the line-
of-sight of the gate. Activation of the reset control shall not
cause the operator to start.
COMM LINK Connection Failure
In dual gate installations, if there is a connection failure between the
two operators, the COMM LINK indicator will blink once a second.
During this condition the gate will not operate, except if triggered by the
FIRE DEPT input, which functions normally.
MGT Obstacle Transmitter Trouble
If any MGT transmitters are used with the operator, their supervision
feature will alert the Controller if there is any trouble with the transmitter.
MGT transmitters send hourly status reports and will send low battery
reports when the transmitter has a low battery. The MGT transmitters
also have a tamper detection switch that will trigger when their case
is opened.
When the Controller detects a low transmitter battery, a tamper signal,
or missing transmitter status reports, the gate will still operate normally,
but the beeper will change as follows:
• The Pre-start Alarm will beep twice as fast.
• The Run Alarm will beep twice as fast and continue for five minutes
after the gate stops.
• The sounder will "chirp" every five seconds when the gate is idle.
Correct the trouble (close case, replace battery, or replace transmitter)
to clear the obstacle transmitter trouble indications.
Maximum Run Time Exceeded
If the Maximum Run Time is exceeded, the Controller stops the operator
the same as if a double obstacle has occurred in an entrapment
condition. The entrapment alarm sounds constantly, and is cleared by
pressing the STOP button or the RESET button on the cover. After the
STOP or RESET button is pressed, because the Maximum Run Time has
been exceeded, the sounder will beep twice every five seconds. The
next operation of the gate will clear the indication.
HSLG Slide Gate Operator Installation Guide
www.LinearGateOpeners.com | (888) 378-1053 | Sales@LinearGateOpeners.com
CONTROLLER ERROR CAUSES AND INDICATIONS
ERROR CAUSE
TWO SAFETY REVERSALS
(ON SINGLE GATE OR ON
EITHER DUAL GATE)
MAXIMUM RUN TIMER
EXCEEDED ON OPENING
MAXIMUM RUN TIMER
EXCEEDED ON CLOSING
COMM LINK FAILURE
GATE FULL OPEN
RESULTING FROM FIRE
DEPT INPUT
FAIL SAFE OR FAIL SECURE
BECAUSE OF BATTERY
VOLTAGE DROP BELOW
21.6 VDC DUE TO AC
POWER LOSS
OTHER CONTROLLER IN
ENTRAPMENT (DUAL GATE)
LOW AC VOLTAGE AT
CONTROLLER
INPUT TRIGGERED DURING
ENTRAPMENT LOCKOUT
COMPATIBILITY PROBLEM
EEPROM PROBLEM
DC MOTOR MISMATCH
MOTOR FAILURE
AC POWER LOSS IN OPEN
OR CLOSE IMMEDIATE
POWER FAIL MODE
MAXIMUM RUN TIMER
EXCEEDED AFTER AC
POWER LOSS
MGT SUPERVISORY
CONDITION (TAMPER, LOW
BATTERY, MISSING HOURLY
STATUS)
- 27 -
ERROR INDICATION
HOW TO CLEAR
En 00, CONTINUOUS
ALARM BEEPER, GATE
PRESS STOP BUTTON
DISABLED
PRESS STOP BUTTON,
En 01, AND MAX RUN
CLEARS CONTINUOUS
LED, CONTINUOUS ALARM
ALARM, THEN DOUBLE
BEEPER, GATE DISABLED
BEEP EVERY 5 SECONDS
UNTIL NEXT OPERATION
PRESS STOP BUTTON,
En 02, AND MAX RUN
CLEARS CONTINUOUS
LED, CONTINUOUS ALARM
ALARM, THEN DOUBLE
BEEPER, GATE DISABLED
BEEP EVERY 5 SECONDS
UNTIL NEXT OPERATION
En 03, AND COMM LINK
LED, CONTINUOUS ALARM
PRESS STOP BUTTON,
BEEPER FOR 1 MINUTE,
CLEARS CONTINUOUS
GATE DISABLED (EXCEPT
ALARM
FOR FIRE DEPT INPUT)
En 04, GATE DISABLED
PRESS STOP BUTTON
BATTERY VOLTAGE MUST
En 05, GATE DISABLED
RISE ABOVE 24 VDC
CLEAR ENTRAPMENT
En 06, GATE DISABLED
ON OTHER CONTROLLER
(PRESS STOP)
RESTORE AC POWER TO
En 07, GATE DISABLED
NORMAL LEVEL
En 08, GATE DISABLED
PRESS STOP BUTTON
UPDATE FIRMWARE AND
En 09, GATE DISABLED
RESET BOTH PAIRED
CONTROLLERS
TRY RESET, CALL TECH.
En 10, GATE DISABLED
SUPPORT
REPROGRAM MOTOR TYPE
OR CHANGE DC MOTOR
En 11, GATE DISABLED
BOARD, NEXT GATE
MOVEMENT WILL RETRY
DC MOTOR CHECK
En 12, GATE DISABLED
REPLACE MOTOR
En 13
REAPPLY AC POWER
BATTERY VOLTAGE MUST
En 14
RISE ABOVE 24 VOLTS
FAST BEEPS DURING
PRESTART, FAST BEEP RUN
CLEARS WHEN MGT
ALARM, CHIRP EVERY 5
CONDITION CLEARS
SECONDS AT IDLE
P1220 X14