General Reporting Codes - Linear DVS-1200 Installation & Programming Instructions

Supervised wireless security console
Table of Contents

Advertisement

✦ The 4 by 2 two-digit communicator reporting code
for each event has a factory set value. These values
may be customized to fi t the specifi c installation and
the reporting requirements of the Central Station
monitoring the system.
✦ If Point ID reporting is enabled (the factory default
setting), each sensor can report a unique alarm and
trouble code.
✦ If Point ID is disabled, the "general" reporting codes
for each event type will be used.
✦ Each programming function is performed with
similar keystrokes. After the system is in Setup
Mode, enter the programming step number and
press HOME, then enter the new value and press
AWAY. For reference, follow the fi gures next to the
programming steps.
✴ If the new value is accepted, a "Bing" will sound. If the new
value is not accepted, a "Double Buzz" will sound.
✦ Making a value 0 causes the event not to
communicate to the Central Station.
✎ NOTE: The reporting codes are fi xed for opening
and closing. A unique code is reserved for the
master and the fi ve restricted user codes. See the
Opening & Closing Reporting Codes Table.

GENERAL REPORTING CODES

✦ Use program Steps #201 - 206 to change the
communicator reporting codes when Point ID is
disabled.
✦ Refer to the General Reporting Codes table to view/
edit the reporting codes for each of the fi ve events.
The factory settings are listed, along with a blank
area to write in the new installation values.
STEPS #201-206
Any value from 0-99 can be programmed for each
event using these steps (enter "0" to stop an event
from reporting).
✎ NOTE: Be careful not to duplicate codes unless the
Central Station requires specifi c codes for certain
types of events.
STEP #
PROGRAMMING FUNCTION
201
GENERAL FIRE REPORT CODE
202
GENERAL EMERGENCY REPORT CODE
203
GENERAL SILENT PANIC REPORT CODE
204
GENERAL BURGLARY REPORT CODE
206
GENERAL TROUBLE REPORT CODE
38
COMMUNICATOR REPORTING CODES
SENSOR EMERGENCY
CONSOLE EMERGENCY
SENSOR FIRE
CONSOLE FIRE
BURGLARY ALARM
SILENT PANIC
FORCE ARM
DURESS
CANCEL
SENSOR LOW BATTERY
SENSOR STATUS TROUBLE
CONSOLE LOW BATTERY
CONSOLE BATTERY RESTORE
2-WAY AUDIO
GENERAL REPORTING CODES
POSSIBLE 4 BY 2 VALUES
0 - 99
0 - 99
0 - 99
0 - 99
0 - 99
General Reporting Codes Table
ADEMCO REPORTING CODES
EVENT
ALARM CODE
E120
E120
E111
E110
E130
E122
E574
E121
E406
E384
E381
E302
R302
E606
xx = SENSOR NUMBER IN EXTENDED REPORT
= PROGRAM
HOME
= STORE
AWAY
2
ABC
PROGRAMMING STEPS
#201 TO #206
PROGRAM
0 - 99 FOR GENERAL
ALARM REPORTING CODE
STORE PROGRAM
FACTORY 4 BY 2 VALUES
1
2
3
4
6
EXTENDED CODE
C0xx
C026
C0xx
C025
C0xx
C0xx
C000
C000
C000
C0xx
C0xx
C000
C000
C000
= REMOVE
TEST
INSTALLATION 4 BY 2 VALUE