Away Mode; Manual Bypassing Of Sensors - Linear DVS-1200 Installation & Programming Instructions

Supervised wireless security console
Table of Contents

Advertisement

AWAY MODE

✦ Use this mode when no one will be staying home.
✦ Each burglary sensor can trigger the siren once per
arming period.
✦ Away Mode causes an instant alarm when any
perimeter sensor is triggered.
✦ Away Mode causes a delayed alarm when any
exit/entry sensor is triggered.
✦ Away Mode causes an instant alarm when any
interior sensors (motion detectors, etc.) are
triggered. The interior sensors will be delayed if a
perimeter delayed sensor is triggered fi rst.
✦ Alarm siren stops automatically after fi ve minutes
and the system will remain armed.
1A. Arm to Away Mode by entering a user code, and
pressing AWAY.
1B. The user can "Quick Arm" to Away Mode from
Home, Chime or Off Mode by pressing AWAY for two
seconds. (Quick arming can be disabled; see the
"Advanced Programming" section of this manual.)
EXIT DELAY (For Leaving the Premises)
✴ When the system is armed to the Away Mode, the Console
will sound a "Gong" and three "Beeps".
✴ During the 60 second Exit Delay, the Console will sound
"Beeps" (double Beeps last 10 seconds) and the AWAY light
will blink.
2A. The Exit Delay gives the user 60 seconds to
leave the premises through an exit/entry door
without triggering an alarm.
2B. Re-entering during the Exit Delay will extend the
Exit Delay another 60 seconds (one time only).
✴ When the Exit Delay is over, the Console will sound one
"Gong" to warn the user that the system is fully armed.
✎ NOTE: The Exit Delay time can be changed; see the
"Advanced Programming" section of this manual.
ENTRY DELAY (For Entering the Premises)
3A. The Entry Delay gives the user 30 seconds to
enter the premises through an exit/entry door
without triggering an alarm.
3B. If a exit/entry sensor is triggered, starting the
Entry Delay, the interior sensors will also become
delayed (this allows motion in the premises
during the Entry Delay).
✴ During the 30 second Entry Delay, the Console will sound
"Beeps".
4. When the Entry Delay is over, the Console will
go into full alarm and sound the siren if it is not
disarmed to the Off or Chime Mode.
✴ If an alarm has occurred while the user was gone, multiple
Beeps will sound after disarming and the sensor light for
the sensor(s) that caused the alarm will fl ash (switch to
Off Mode again or re-arm the Console to stop the fl ashing
alarm memory light).
✎ NOTE: The Entry Delay time can be changed; see the
"Advanced Programming" section of this manual.

MANUAL BYPASSING OF SENSORS

✦ Manual bypassing of sensors in the Away Mode
allows arming of the system with open doors and
windows, while still having perimeter protection with
other closed doors and windows.
1. The Console will resist arming with open door or
window sensors.
✴ Four high-low Beeps to warn the user that something is
open and the system will remain in the previous mode.
✴ Lit sensor status indicators show which sensors are open.
2. To manually bypass the open sensors, arm the
system again within fi ve seconds.
✴ A "Gong" and three "Beeps" will sound, the AWAY indicator
will light, and the open sensors will be bypassed.
✎ WARNING: Bypassed sensors cannot cause an
alarm. Closing the sensor removes the bypass.
AWAY MODE
START HERE
AWAY
DONE
QUICK ARM
START HERE
AWAY
DONE
(OPTIONAL)
YOUR
USER
CODE
1 GONG
& 3 BEEPS
HOLD
DOWN
1 GONG
& 3 BEEPS
19