Making A Sensor Perform A Different Function - Linear DVS-1200 Installation & Programming Instructions

Supervised wireless security console
Table of Contents

Advertisement

MAKING A SENSOR PERFORM A DIFFERENT FUNCTION

✦ Sensors can be reprogrammed to perform different
sensor functions.
✦ The sensor must have already been programmed
into the Console (see "Adding sensors to the
System" for details).
1. Start with the Console in Test Mode.
2. Enter the master user code then press TEST.
✴ A "Gong" and fi ve "Beeps" will sound.
✴ The sensor status indicators will light for each sensor
programmed into the Console.
3. Enter the sensor number from 01-12 (you must
enter two digits, example: 5 = 05).
✴ The sensor status indicator light will fl ash for the sensor
number selected.
4. Choose a sensor function number from the Sensor
Function Table.
5. Press HOME, the new sensor function number, then
AWAY.
✴ A "Bing" tone will sound and the sensor status indicator will
light steady.
6. Enter another sensor number or exit Setup Mode
by pressing the
seconds.
PROGRAMMING INFORMATION
FUNC-
SENSOR FUNCTION
TION #
1
AUTOMATION
2
EMERGENCY
3
PANIC
4
FIRE
5
PERIMETER
6
EXIT/ENTRY
7
INTERIOR
8
CHIME
2-BUTTON ARM/DISARM (LEFT)
9
2-BUTTON AUTOMATION (RIGHT)
EMERGENCY (BOTH BUTTONS)
2-BUTTON ARM (LEFT)
10
2-BUTTON DISARM (RIGHT)
EMERGENCY (BOTH BUTTONS)
11
ENVIRONMENTAL
12
INTERIOR HOME
CAN BE HOME MODE USING PROGRAMMING STEP 50
‡ CAN BE CHIME MODE USING PROGRAMMING STEP 51
24
key then press OFF for three
OFF MODE
DEACTIVATED
DEACTIVATED
DEACTIVATED
LEFT BUTTON SWITCHES SYSTEM TO AWAY MODE †
IF ALARM MEMORY IS ACTIVE, SWITCHES SYSTEM TO OFF MODE ‡
LEFT BUTTON SWITCHES SYSTEM TO AWAY MODE †
IF ALARM MEMORY IS ACTIVE, SWITCHES SYSTEM TO OFF MODE ‡
DEACTIVATED
SENSOR FUNCTION TABLE
SENSOR OPERATION IN EACH CONSOLE MODE
CHIME MODE
ACTIVATES AND DEACTIVATES THE AUTOMATION OUTPUT
ARMED 24-HOURS - TRIGGERS EMERGENCY ALARM
ARMED 24-HOURS - TRIGGERS SILENT PANIC ALARM
ARMED 24-HOURS - TRIGGERS FIRE ALARM
CHIME
CHIME
DEACTIVATED
CHIME
ARMED 24-HOURS - TRIGGERS ANNUNCIATION ONLY
DEACTIVATED
START IN TEST
MASTER
USER
CODE
1 GONG &
TEST
5 BEEPS
SENSOR
NUMBER
FOR
FUNCTION
CHANGE
HOME
NEW
FUNCTION
NUMBER
FOR SENSOR
AWAY
1 BING
DONE
HOME MODE
AWAY MODE
INSTANT BURGLARY ALARM
DELAYED BURGLARY ALARM
INSTANT BURGLARY ALARM
UNLESS ACTIVATED DURING
DEACTIVATED
AN ENTRY DELAY, THEN IT IS
LEFT BUTTON SWITCHES SYSTEM TO OFF MODE ‡
RIGHT BUTTON SWITCHES SYSTEM TO OFF MODE ‡
INSTANT BURGLARY ALARM
DELAYED

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents