TELEPHONE LINE CONNECTION

✦ Connect the Console to the telephone line if the
system is monitored, requires 2-way audio, or
requires telephone remote command.
✦ Telephone RING & TIP terminals are for connection
to the incoming telephone line.
✦ Seized telephone ring & tip are for connection
to local telephone sets. When the communicator
activates, all the local telephone sets will be
disconnected to prevent an off-hook telephone on
the premises from blocking the communicator call.
1. Install a USOC RJ31-X or RJ38-X jack to the
telephone system near the Console.
2. Route an appropriate modular telephone line cord
from the jack to the Console.
3. Route the line cord through the Console's wiring
access hole.
4. Connect the incoming telephone line wires to the
Console's telephone terminal block TIP and RING
terminals.
5. Connect the local telephone set wires to the
Console's telephone terminal block SEIZED TIP
and SEIZED RING terminals.
✦ When directly connecting (without a telephone line)
to the DVS-1200 with the RA-2400 remote access
software (Version 1.3 or later), disconnect the incoming
telephone line and connect the modem to the panel's
TIP and RING terminals (with the modem's red & green
phone line wires). Press the EMERGENCY key while
in Test Mode to cause the panel to connect to the
modem.

AUTOMATION OUTPUT CONNECTION (OPTIONAL)

✦ The Console provides a Automation Output to
control lights, devices and appliances.
✦ Automation Output can connect to most popular
home automation devices and other simple
electronic devices (see fi gure).
✦ Press
to turn the Automation Output on, press
again to turn it off.
Programmable Options
✦ There are many programmable options for the
Automation Output.
✦ The Automation Output can be programmed for a
variety of useful functions, such as: fl ashing during
alarm, fl ashing after an alarm, on while armed, or,
on during exit/entry delays.
✦ See the "Advanced Programming" section of this
manual for details on changing the function of the
Automation Output.
10
TELEPHONE
TERMINAL
LINEAR SECURITY CONSOLE MODEL DVS-1200
BLOCK
OPTIONAL
VOICE MODULE
MODEL: VB-2
SEIZED
TIP (T1)
DVS-1200
TELEPHONE
TERMINAL
BLOCK
BROWN
GRAY
8-PIN
MODULAR
PHONE CORD
8-POSITION
USOC RJ31-X
(OR RJ38-X)
JACK
R
T
TO TELEPHONE
NETWORK
LINEAR SECURITY CONSOLE MODEL DVS-1200
MAIN
TERMINAL
BLOCK
OPTIONAL
VOICE MODULE
MODEL: VB-2
EXAMPLE AUTOMATION OUTPUT HOOK-UPS
X-10
LINEAR RB-90
BURGLAR ALARM
X-10
RELAY MODULE
INTERFACE
(CAN CONTROL
HOUSE LIGHTS
THROUGH X-10
SYSTEM)
H/A +
H/A -
H/A +
TELEPHONE TERMINAL BLOCK
SEIZED RING
SEIZED TIP
TO LOCAL
PHONES
SEIZED
LINE
LINE
RING (R1)
RING (R)
TIP (T)
RED
GREEN
BLUE, ORANGE
BLACK, AND
YELLOW NOT
USED
SHORTING BAR
R1
R
T
T1
SHORT REMOVED
ON PLUG
INSERTION
1
2
3
4
5
6
7
8
T1
TO LOCAL
TELEPHONE
R1
SETS
CONNECT TELEPHONE LINE
TO THE TELEPHONE
TERMINAL BLOCK
MINUS H/A TERMINAL WILL SWITCH
TO GROUND WHEN AUTOMATION
OUTPUT IS ACTIVATED
MAIN TERMINAL BLOCK
LIGHT EMITTING
DIODE (L.E.D.)
POSITIVE H/A TERMINAL PROVIDES
+12 VOLTS DC AND IS CURRENT
LIMITED AT 30 MILLIAMPS MAXIMUM
YOUR
LOAD
POWER
SOURCE
H/A -
H/A +
H/A -
TIP
RING
TO PHONE
LINE
AC
AC
EXT. SPKR
(-)
H/A -
H/A +
RELAY N.O.
RELAY DRY
LIGHT
EMITTING
DIODE
(L.E.D.)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents