Lincoln Electric VANTAGE SVM178-B Service Manual page 227

Lincoln electric welding system user manual
Table of Contents

Advertisement

F-39
OUTPUT RECTIFIER BRIDGE TEST(CONTINUED)
WELD WINDING
LEAD CONNECTIONS
W1 W6
W3
W2
W5
9. Using the 7/16" wrench, remove the stator leads
from the three AC terminals.
reassembly. Note leads and AC terminals place-
ment for reassembly. See Figure F.15.
10. Electronically isolate the 3 AC terminals leads by
carefully bending them out into "free air"
11. With an ohmmeter or diode tester, check each of
the 3 AC terminals to their respective heat sinks.
12. Reverse the tester leads and check the diodes
again. Diodes should have a low resistance in one
polarity and very high resistance in the opposite
polarity. See diode test Table F.2.
* One open diode will not be detected.
13. Replace rectifier bridge if any "shorted" or "open"
diode as tests indicate.
14. Replace the AC terminals and stator leads.
Assemble the washers and nuts.
TROUBLESHOOTING AND REPAIR
FIGURE F.14 – DIODE LEAD REMOVAL
W4
Label leads for
VANTAGE® 500
15. Replace the lower front panel and output leads.
16. Replace the upper control panel and secure.
17. Replace the front left and right case sides.
* One open diode will not be detected.
F-39

Hide quick links:

Advertisement

Table of Contents
loading