A4.2
TECHNICAL SPECIFICATIONS - Vantage 500 CUMMINS (K2272-1)
Make /Model
Description
Cummins
4 cylinder
B3.3
56HP (42 kw)
Diesel Engine
@ 1800 RPM
Duty Cycle
100%
60%
50%
OUTPUT @ 104°F(40°C) - WELDER AND GENERATOR
Height
(2)
42.0 in
(1066.8 mm)
1.
Output rating in watts is equivalent to volt-amperes at unity power factor.
Output voltage is within +/- 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.
2.
Top of Enclosure. Add 8.8" (223.5mm) for exhaust.
INSTALLATION
INPUT - DIESEL ENGINE
Speed (RPM)
High Idle 1900
Low Idle 1425
Full Load 1800
RATED OUTPUT @ 104°F(40°C) - WELDER
Welding Output
500 Amps (DC multi-purpose)
550 Amps (DC multi-purpose)
575 Amps (DC multi-purpose)
Welding Range
30 - 575 Amps CC/CV
20 - 250 Amps TIG
Open Circuit Voltage
60 Max OCV @ 1900 RPM
Auxiliary Power
120/240 VAC
12,000 WATTS, 60 Hz.
PHYSICAL DIMENSIONS
Width
31.5 in.
(800.1mm)
VANTAGE® 500
Displacement
Starting
System
199 cu. in
12VDC battery
(3.3L)
& Starter
Bore x Stroke
3.74" x 4.53"
(95mm x 115mm)
Volts at Rated Amps
40 Volts
36 volts
35 volts
(1)
Depth
63.1 in.
(1603mm)
A4.2
Capacities
Fuel
(25 US gal)
94.6L
Oil:
(2 US gal)
7.5L
Coolant:
(2.6 US gal)
11.8L
Weight
1605 lbs.
(728kg)
(Approx)