FLUE INSTALLATION

TYPES OF FLUE INSTALLATIONS

Consult the 'Energysaver Space Heater Co-Axial Flue Systems Installation Manual' included with
the 'On Wall' or 'Direct' flue kits for detailed flue installation instructions. Use only Rinnai Flue
IMPORTANT
components with this appliance.
The following configurations are currently available. For alternative configurations contact Rinnai.
DIRECT / EXTENDED
SIDEWAYS
EXTERNAL WALL
IN-WALL
UNDER FLOOR
The Energysaver Heater comes supplied with a standard back cover kit. For 'Sideways' and
'Underfloor' installations, refer to the 'Energysaver Space Heater Co-Axial Flue System
NOTE
Installation Manual' for details of the alternative back cover kit required.
Flue is NOT to be terminated under the floor or in a roof space. 'Down & Out' and vertical 'through
roof' flue installations are permitted ONLY when the flue terminal is located externally.
DO NOT
For horizontal installations including 'Down & Out' flue systems there must be a continuous fall of
at least 2° to the termination point to drain condensate.
WARNING
Flue terminal must be at least 300 mm above the ground in accordance with AS/NZS 5601, Clause
6.9 and Fig. 6.2.
All terminations exceeding a vertical height of 1.5 metres must incorporate a condensate trap.
The 'AIR INTAKE' hose MUST NOT BE CUT OR SHORTENED. For more detailed information refer
to 'Energysaver Space Heater Co-Axial Flue Systems Installation Manual'.
Rinnai
Option A (Direct)
Direct Flue Kit
Components
Direct Flue Kit
Co-Ax Pipe 900mm #
Back Cover Set
(see note below)
Option A (Vertical Termination)
Direct Flue Kit
Co-Ax Pipe 900mm #
Bend (2 x 45º)
Condensate Trap
Roof Cowl
Option A (Direct)
Vertical Adaptor Kit §
Co-Ax Pipe 900mm #
Roof Cowl
Components
Direct Flue Kit
Co-Ax Pipe 900mm #
Bend (2 x 45º)
Back Cover Set
(see note below)
Components
ESDFK
Co-Ax Pipe 900mm (Optional) #
ESDFK
ESPIPE900
Components
ESDFK
ESPIPE900
Co-Ax Pipe 900mm #
ESBEND
ESCONDK
Condensate Trap
ESROOFCOWL
Components
ESFKITIW
Vertical Adaptor Kit §
(ESKIT03)
Co-Ax Pipe 900mm #
ESPIPE900
ESROOFCOWL
ESDFK
ESPIPE900
§ Includes Condensate Trap (ESCONDK)
ESBEND
25
Option B (Direct Extended)
Direct Flue Kit
Option B (On Wall Termination)
Direct Flue Kit
Bend (2 x 45º)
Option B (Offset)
Bend (2 x 45º)
Roof Cowl
ESROOFCOWL
# Order lengths as required
ESDFK
ESPIPE900
ESDFK
ESPIPE900
ESBEND
ESCONDK
ESFKITIW
(ESKIT03)
ESPIPE900
ESBEND
ES_FT_OIM