Flue Installation Configurations - Rinnai RHFE-309FT Operation And Installation Manual

Energysaver space heaters
Table of Contents

Advertisement

FLUE INSTALLATION CONFIGURATIONS

.
Consult the 'Energysaver
included with the 'On Wall' or 'Direct' flue kits for detailed flue installation
NOTE
instructions. Use only Rinnai Flue components with this appliance.
The following configurations are currently available. For alternative configurations contact Rinnai
DIRECT / EXTENDED
SIDEWAYS
EXTERNAL WALL
IN-WALL
UNDER FLOOR
# Order lengths as required
The Energysaver Heater comes supplied with a standard back cover set. For
'Sideways' & 'Underfloor' installations, refer to the 'Energysaver Space Heater Co-
NOTE
Axial Flue System Installation Manual' for the alternative back cover set required.
Flue is NOT to be terminated under the floor or in a roof space.
'Down & Out' and vertical 'through roof' flue installations are permitted ONLY when
DO NOT
the flue terminal is located externally.
For horizontal installations there must be a continuous fall of at least 2° to the
termination point to drain condensate.
WARNING
All terminations exceeding a vertical height of 1.5 metres must incorporate a
condensate trap.
'Down & Out' Flue systems must have a continuous fall of at least 2° to the
termination point to drain condensate. Flue terminal must be at least 300 mm above
the ground in accordance with AS 5601, Clause 5.13.6.2 and Fig. 5.3.
Rinnai Australia
®
Space Heater Co-Axial Flue Systems Installation Manual'
Option A (Direct)
Direct Flue Kit
Components
Direct Flue Kit
Co-Ax Pipe 900mm #
Back Cover Set
(see note below)
Option A (Vertical Termination)
Direct Flue Kit
Co-Ax Pipe 900mm #
Bend (2 x 45º)
Condensate Trap
Roof Cowl
Option A (Direct)
Vertical Adaptor Kit §
Co-Ax Pipe 900mm #
Roof Cowl
Components
Direct Flue Kit
Co-Ax Pipe 900mm #
Bend (2 x 45º)
Back Cover Set
(see note below)
§ Includes Condensate Trap (ESCONDK)
Components
Option B (Direct Extended)
ESDFK
Direct Flue Kit
Co-Ax Pipe 900mm
(Optional) #
ESDFK
ESPIPE900
Components
Option B (On Wall Termination)
ESDFK
Direct Flue Kit
ESPIPE900
Co-Ax Pipe 900mm #
ESBEND
Bend (2 x 45º)
ESCONDK
Condensate Trap
ESROOFCOWL
Components
ESFKITIW
Vertical Adaptor Kit §
ESPIPE900
Co-Ax Pipe 900mm #
ESROOFCOWL
Bend (2 x 45º)
Roof Cowl
ESDFK
ESPIPE900
ESBEND
21
Energysaver® - Operation & Installation Manual
ESDFK
ESPIPE900
ESDFK
ESPIPE900
ESBEND
ESCONDK
Option B (Offset)
ESFKITIW
ESPIPE900
ESBEND
ESROOFCOWL

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rhfe-559ft

Table of Contents