FLUE INSTALLATION CONFIGURATIONS

Consult the 'Energysaver Space Heater Co-Axial Flue Systems Installation Manual' included
with the 'On Wall' or 'Direct' flue kits for detailed flue installation instructions. Use only Rinnai
NOTE
Flue components with this appliance.
The following configurations are currently available. For alternative configurations contact Rinnai.
DIRECT / EXTENDED
SIDEWAYS
EXTERNAL WALL
IN-WALL
UNDER FLOOR
# Order lengths as required
The Energysaver Heater comes supplied with a standard back cover set. For 'Sideways' &
'Underfloor' installations, refer to the 'Energysaver Space Heater Co-Axial Flue System
NOTE
Installation Manual' for the alternative back cover set required.
Flue is NOT to be terminated under the floor or in a roof space.
'Down & Out' and vertical 'through roof' flue installations are permitted ONLY when the flue
DO NOT
terminal is located externally.
For horizontal installations there must be a continuous fall of at least 2° to the termination point
to drain condensate.
WARNING
All terminations exceeding a vertical height of 1.5 metres must incorporate a condensate trap.
'Down & Out' Flue systems must have a continuous fall of at least 2° to the termination point
to drain condensate.
Flue terminal must be at least 300 mm above the ground in accordance with AS/NZS 5601,
Clause 6.9 and Fig. 6.2.
AT NO TIME MUST THE 'AIR INTAKE' HOSE BE CUT OR SHORTENED. For more detailed
information refer to 'Energysaver Space Heater Co-Axial Flue Systems Installation Manual'
Rinnai
Option A (Direct)
Direct Flue Kit
Components
Direct Flue Kit
Co-Ax Pipe 900mm #
Back Cover Set
(see note below)
Option A (Vertical Termination)
Direct Flue Kit
Co-Ax Pipe 900mm #
Bend (2 x 45º)
Condensate Trap
Roof Cowl
Option A (Direct)
Vertical Adaptor Kit §
Co-Ax Pipe 900mm #
Roof Cowl
Components
Direct Flue Kit
Co-Ax Pipe 900mm #
Bend (2 x 45º)
Back Cover Set
(see note below)
§ Includes Condensate Trap (ESCONDK)
Components
Option B (Direct Extended)
ESDFK
Direct Flue Kit
Co-Ax Pipe 900mm
(Optional) #
ESDFK
ESPIPE900
Components
Option B (On Wall Termination)
ESDFK
Direct Flue Kit
ESPIPE900
Co-Ax Pipe 900mm #
ESBEND
Bend (2 x 45º)
ESCONDK
Condensate Trap
ESROOFCOWL
Components
ESFKITIW
Vertical Adaptor Kit §
(ESKIT03)
Co-Ax Pipe 900mm #
ESPIPE900
Bend (2 x 45º)
ESROOFCOWL
Roof Cowl
ESDFK
ESPIPE900
ESBEND
24
ESDFK
ESPIPE900
ESDFK
ESPIPE900
ESBEND
ESCONDK
Option B (Offset)
ESFKITIW
(ESKIT03)
ESPIPE900
ESBEND
ESROOFCOWL
Energysaver Operation & Installation Manual