DX0.5
and down using the arrowed buttons or values can be entered by directly typing them into the window. Values can range from
5ms up to 200. Steps are 1ms from 5 to 20ms, 5ms from 20 to 30ms, 10ms from 30 to 100ms then 20ms from 100 to 200.
Release is the time in seconds that it takes the gain to return to normal after levels drop back below the limiter threshold. A
slower release helps to make the limiter less audible reducing the "pumping" sound that is often audible. As with threshold and
attack the values can be cycled up and down using the arrowed buttons or values can be entered by directly typing them into
the window. Values can range from 0.1s up to 3s in steps of 0.1seconds.
HAM09224 User Guide V1.0
USER GUIDE
45