A-4

INPUT CONNECTION

WARNING
Only a qualified electrician should
connect the input leads to the
POWER
Connections should be made in
accordance with all local and
national electrical codes and the connection dia-
gram located on the inside of the reconnect
access door of the machine. Failure to do so may
result in bodily injury or death.
------------------------------------------------------------------------
The supply cable provided with the Power Wave C300
CE is rated for 450 VAC (line-to-neutral). Replace the
supply cable in accordance with all national and local
codes when operating at higher voltages.
A 15 ft. (4.6m) power cord is provided and wired into
the machine.
Single Phase Input not supported.
Three Phase Input
Connect green/yellow lead to ground per National
Electric Code.
Connect grey, brown and black leads to power.

INPUT FUSE AND SUPPLY WIRE

CONSIDERATIONS
Refer to Specification Section for recommended fuse,
wire sizes and type of the copper wires. Fuse the
input circuit with the recommended super lag fuse or
delay type breakers (also called "inverse time" or
"thermal/magnetic" circuit breakers). Choose input
and grounding wire size according to local or national
electrical codes. Using input wire sizes, fuses or cir-
cuit breakers smaller than recommended may result in
"nuisance" shut-offs from welder inrush currents, even
if the machine is not being used at high currents.

INPUT VOLTAGE SELECTION

The POWER WAVE® C300 CE automatically adjusts
to work with different input voltages. No reconnect
switches settings are required.
INSTALLATION
WAVE®
C300
CE.
POWER WAVE® C300 CE
WARNING
The POWER WAVE® C300 CE
ON/OFF switch is not intended as a
service disconnect for this equip-
ment. Only a qualified electrician
should connect the input leads to
the POWER WAVE® C300 CE.
Connections should be made in accordance with
all local and national electrical codes and the con-
nection diagram located on the inside of the
reconnect access door of the machine. Failure to
do so may result in bodily injury or death.
------------------------------------------------------------------------

POWER CORD REPLACEMENT

WARNING
Only a qualified electrician should
connect the input leads to the
POWER
Connections should be made in
accordance with all local and
national electrical codes and the
connection diagram located on the inside of the
reconnect access door of the machine. Failure to
do so may result in bodily injury or death.
------------------------------------------------------------------------
If the input power cord is damaged or needs to be
replaced an input power connection block is located in
the access panel under the wire spool.
ALWAYS
CONNECT
GROUNDING LUG (LOCATED INSIDE THE
ACCESS PANEL) TO A PROPER SAFETY (EARTH)
GROUND.
FIGURE A.1