A-4
3. The POWER MIG is shipped with a 10ft.(3.05m)
input cable and plug connected to the welder.
Using the instructions in Figure A.2, have a quali-
fied electrician connect the receptacle or cable to
the input power lines and the system ground per
the U.S. National Electrical Code and any applica-
ble local codes. See "Technical Specifications"
at the beginning of this chapter for proper wire
sizes. For long runs over 100ft. (30.48m), larger
copper wires should be used. Fuse the two hot
lines with super lag type fuses as shown in the fol-
lowing diagram. The center contact in the recepta-
cle is for the grounding connection. A green wire in
the input cable connects this contact to the frame of
the welder. This ensures proper grounding of the
welder frame when the welder plug is inserted into
the receptacle.
INSTALLATION
FIGURE A.1 — Triple Voltage Machine Input Connections
POWER MIG 300
FIGURE A.2 — Receptacle Diagram
CONNECT TO A SYSTEM
GROUNDING WIRE. SEE
THE UNITED STATES
NATIONAL ELECTRICAL
CODE AND/OR LOCAL
CODES FOR OTHER
DETAILS AND MEANS FOR
PROPER GROUNDING.
CONNECT TO HOT WIRES
OF A THREE-WIRE, SINGLE
PHASE SYSTEM OR TO ONE
PHASE OF A TWO OR
THREE PHASE SYSTEM.
A-4