Stop Bits; Protocol - Intermec EasyCoder PM4i User Manual

Bar code label printer
Hide thumbs Also See for EasyCoder PM4i:
Table of Contents

Advertisement

Stop Bits

The number of stop bits specifi es how many bits will defi ne the end of a
character. There are two options:
• 1
• 2

Protocol

XON/XOFF (default)
In the XON/XOFF protocol, data fl ow control is achieved by using
XON (DC1) and XOFF (DC3) characters. Message blocks are not
required to be bracketed by the Start of Text (STX) and End of Text
(ETX) characters. However, at power up or after a reset all characters
except ENQ or VT will be ignored until an STX is detected. The mes-
sage length in this protocol is unrestricted. That is, the printer processes
information as it is being downloaded and stops when there is no more
information.
XON/XOFF protocol conforms to generally accepted industry standards.
No end-of-message response is sent to the host other than XOFF. An
XON will be sent on power up.
Since DC1 and DC3 are used for data fl ow control, the printer status
characters are different than those of the Standard Protocol. If the host
ignores the printer's XOFF, the printer will resend an XOFF after receiv-
ing every 15 characters from the host.
Condition
Buffer already full
Printhead raised
Ribbon fault
No label stock
Buffer now full
Printhead hot
Label at strip pin
Label skipping
Printing