Lincoln Electric CLASSICII SVM125-A Service Manual page 34

Lincoln electric welder user manual
Table of Contents

Advertisement

C-6
CONNECTION OF THE LN-25 TO THE
CLASSIC II USING K867 UNIVERSAL
ADAPTER (SEE FIGURE C.3.)
1. Shut the welder off.
2. Connect the electrode cable from the LN-25 to the
"+" terminal of the welder. Connect the work cable
to the "CV-" terminal of the welder.
NOTE: Welding cable must be sized for current and
duty cycle of application.
NOTE: Figure C.3 shows the electrode connected for
positive polarity. To change polarity, shut the
welder off and reverse the electrode and work
cables at the Classic II output terminals.
Reverse the LN-25 polarity switch.
3. Connect the K867 Universal adapter to the K432-L
cable and the 14 pin amphenol of the Classic II as
indicated in Figure C.3.
Classic II Output
Terminals are on
Opposite Side
INSTALLATION
FIGURE C.3
CLASSIC II/LN-25 CONNECTION DIAGRAM
14 PIN
AMPHENOL
+
CV-
K867 UNIVERSAL
ADAPTER PLUG
TO
WORK
Splice Leads and Insulate
ELECTRODE CABLE
CLASSIC II
4. Connect the K433 to the LN-25. Mount the K433
to the welder according to instructions included
with the K433 kit.
5. Place the IDLER switch in the "HIGH" position.
CAUTION
Any increase of the high idle engine RPM by changing
the governor setting or overriding the throttle linkage
will cause an increase in the AC auxiliary voltage. If
this voltage goes over 140 volts, wire feeder control
circuits may be damaged. The engine governor set-
ting is preset at the factory — do not adjust above
RPM specifications listed in this manual.
6. Adjust wire feed speed and voltage at the LN-25.
SPARE
82
Insulate Each
81
Unused Lead
42
Individually
41
21
31
31
32
32
2
2
4
4
GND
GND
75
75
76
76
77
77
C-6
K433
K432-"L" CABLE
LN-25 WIRE FEEDER
WITH K431 OPTION

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Classic ii