C-5
CONNECTION OF THE LN-7 TO THE
CLASSIC II USING K584 INPUT CABLE
ASSEMBLY (SEE FIGURE C.2.)
1. Shut the welder off.
2. Connect the electrode cable from the LN-7 to the
"+" terminal of the welder. Connect the work cable
to the "CV-" terminal of the welder.
NOTE: Welding cable must be sized for current and
duty cycle of application.
NOTE: Figure C.2 shows the electrode connected for
positive polarity. To change polarity, shut the
welder off and reverse the electrode and work
cables at the Classic II output terminals .
3. Connect the input cable from the K584-XX Input
Cable Assembly to the 14 pin amphenol on the
K864 adapter and the input cable plug on the LN-
7.
4. Connect the K864 adapter to the 14 pin amphenol
on the Classic II.
5. Place the IDLER switch in the "HIGH" position.
CLASSIC II/LN-7 WITH K584 INPUT CABLE ASSEMBLY CONNECTION DIAGRAM
Classic II Output
Terminals are on
Opposite Side
ACCESSORIES
Any increase of the high idle engine RPM by changing
the governor setting or overriding the throttle linkage
will cause an increase in the AC auxiliary voltage. If
this voltage goes over 140 volts, wire feeder control
circuits may be damaged. The engine governor set-
ting is preset at the factory — do not adjust above
RPM specifications listed in this manual.
6. Adjust wire feed speed and voltage at the LN-7.
NOTE: For remote control, a K857 control is
When the welder is in local control, the electrode is
always "HOT."
FIGURE C.2
14 PIN
AMPHENOL
+
CV-
K864
ADAPTER
TO
WORK
ELECTRODE CABLE
TO LN-7
CLASSIC II
CAUTION
required. Connect it to the K864 adapter.
CAUTION
LN-7
CONTROL
14 PIN
BOX
AMPHENOL
K584-"L" INPUT CABLE
6 PIN
AMPHENOL
K857
REMOTE CONTROL
C-5