Toshiba RAV-SM562BT-E Service Manual/Integration page 36

Air conditioner split type
Hide thumbs Also See for RAV-SM562BT-E:
Table of Contents

Advertisement

RAV-SM802UT-E, RAV-SM802BT-E, RAV-SM802CT-E / RAV-SP802AT-E
Outer diameter of refrigerant pipe
Gas side ØA
Liquid side ØB
15.9mm
9.5mm
TS sensor
Accumulator
(1500cc)
Rotary compressor
(DA220A2F-20L)
Pressure
(MPa)
Pd
Standard
2.72
Cooling
Overload
3.57
Low load
1.89
Standard
2.58
Heating
Overload
3.49
Low load
2.30
4 poles are provided to this compressor.
*
The compressor frequency (Hz) measured with a clamp meter is 2 times of revolutions (rps) of the compressor.
Refrigerant pipe
at gas side
Outer dia. ØA
Packed valve
Pd
Outer dia. ØA
Strainer
TD sensor
4-way valve
(STF-0213Z)
Muffler
Ø25 × L210
Ø25 × L160
Pipe surface temperature (°C)
Discharge
Suction
Ps
(TD)
(TS)
0.93
74
12
1.10
80
21
0.74
34
7
0.68
72
4
1.22
79
19
0.25
91
–17
Indoor unit
Air heat exchanger
TC sensor
* The refrigerating cycle of the indoor units differs according to
the models to be combined. For the refrigerating cycles of the
other indoor units, refer to the corresponding Service Manuals
described in the list on the cover.
Outdoor unit
TO sensor
TE
sensor
Heat exchangerØ8
1 row 30 stages
FP1.3 flat fin
Indoor heat
Outdoor heat
exchanger
exchanger
(TC)
(TE)
11
40
17
52
2
12
41
2
55
16
37
–19
– 36 –
TCJ
sensor
Refrigerant pipe
at liquid side
Outer dia. ØB
Packed valve
Outer dia. ØB
Modulating
(PMV)
(SKV-18D26)
Strainer
Capillary
Ø3×Ø2×
L530
Indoor/Outdoor temp.
Compressor
revolutions per
Indoor
second (rps)
fan
Indoor
55
HIGH
27/19
47
HIGH
32/24
24
LOW
18/15.5
62
HIGH
20/–
28
LOW
30/–
90
HIGH
15/–
Min.
Max.
5m
50m
Ps
R410A 2.1 kg
Cooling
Heating
conditions
(DB/WB) (°C)
Outdoor
35/–
43/–
–5/–
7/6
24/18
–15/(70%)