Applicable Controls - Toshiba MMK-AP0074MH-E Service Manual

Hide thumbs Also See for MMK-AP0074MH-E:
Table of Contents

Advertisement

SMMS High-Wall Type
11.

Applicable Controls

A wired remote controller is necessary for this function. This function cannot be operate with a wireless
remote controller.
REQUIREMENT
• When this air conditioner is used for the first
time, it takes approx. 5 minutes until the remote
controller becomes available after power-on.
This is normal.
<When power is turned on for the first time
after installation>
It takes approx. 5 minutes until the remote
controller becomes available.
Approx. 5 minutes
Power
"SETTING"
"SETTING"
Remote
flashes
goes out
controller is
on
available
<When power is turned on for the second (or
later) time>
It takes approx. 1 minute until the remote
controller becomes available.
Approx. 1 minutes
Power
"SETTING"
"SETTING"
Remote
on
flashes
goes out
controller is
available
• Normal settings were made as factory default.
Change the indoor unit settings as required.
• Use the wired remote controller to change the
settings.
* The settings cannot be changed using the wireless
remote controller, sub remote controller, or
remote-controller less system (for central remote
controller only). Therefore, install the wired remote
controller to change the settings.
27-EN
Installation Manual
Basic procedure for changing
settings
Change the settings while the air conditioner is not
working.
(Stop the air conditioner before making settings.)
The display content for setting differs from that on
the former types of remote controller (RBC-
AMT21E / AMT31E). (The number of CODE No.
has increased.)
1
3
4
6
1
5
2
1
Push
button and "TEMP."
button
simultaneously for at least 4 seconds.
After a while, the display flashes as shown in the
figure.
Confirm that the CODE No. is [01].
• If the CODE No. is not [01], push
button to
erase the display content, and repeat the
procedure from the beginning.
(No operation of the remote controller is accepted
for a while after
button is pushed.)
(While air conditioners are operated under the
group control, "ALL" is displayed first. When
is pushed, the indoor unit number
displayed following "ALL" is the header unit.)
(* Display content varies with
the indoor unit model.)
– 27 –
SMMS High-Wall Type
2
Each time
button is pushed, indoor
unit numbers in the control group change
cyclically. Select the indoor unit to change
settings for.
The fan of the selected unit runs and the louvers start
swinging. The indoor unit for change settings can be
confirmed.
3
Specify CODE No.[
] with "TEMP."
/
buttons.
4
Select SET DATA [
] with "TIME"
/
buttons.
5
Push
button. When the display changes
from flashing to lit, the setup is completed.
• To change settings of another indoor unit, repeat
2
from Procedure
.
• To change other settings of the selected indoor
3
unit, repeat from Procedure
.
Use
button to clear the settings.
To make settings after
button was pushed,
2
repeat from Procedure
.
6
When settings have been completed, push
button to determine the settings.
When
button is pushed, "SETTING" flashes and
then the display content disappears and the air
conditioner enters the normal stop mode.
(While "SETTING" is flashing, no operation of the
remote controller is accepted.)
– 28 –
Installation Manual
Filter sign setting
According to the installation condition, the lighting
time of the filter sign (Notification of filter cleaning)
can be changed.
Follow to the basic operation procedure
1
2
3
4
5
6
(
).
3
• For the CODE No.. in Procedure
, specify [01].
4
• For the SET DATA in Procedure
, select the
SET DATA of filter sign term from the following
table.
SET DATA
Filter sign term
0000
None
0001
150 H (Factory default)
0002
2500 H
0003
5000 H
0004
10000 H
To secure better effect of heating
When it is difficult to obtain satisfactory heating due
to installation place of the indoor unit or structure of
the room, the detection temperature of heating can
be raised. Also use a circulator, etc. to circulate
heat air near the ceiling.
Follow to the basic operation procedure
1
2
3
4
5
6
(
).
3
• For the CODE No.. in Procedure
, specify [06].
4
• For the SET DATA in Procedure
, select the
SET DATA of shift value of detection
temperature to be set up from the table below.
SET DATA
Detection temp shift value
0000
No shift
0001
+1 °C
0002
+2 °C (Factory default)
0003
+3 °C
0004
+4 °C
0005
+5 °C
0006
+6 °C
28-EN