Printing Troubles - Intermec EasyCoder PF2i Service Manual

Industrial printers
Hide thumbs Also See for EasyCoder PF2i:
Table of Contents

Advertisement

Chapter 15—Troubleshooting

15.12 Printing Troubles

228
The best way to start is to get an overall check of the printout quality by
printing a series of test labels in the Test Mode.
If you suspect a defective printhead, you can check it out using the
following Intermec Fingerprint instructions (see Intermec Fingerprint v8.xx,
Programmer's Reference Manual):
• FUNCTEST$ ("HEAD")
• HEAD
• SYSVAR(21)
• SYSVAR(22)
Description:
No printout at all.
Possible Causes and Suggested Remedies:
• Bad connection.
- Is the cable between the printhead and P5 on the Power Supply Unit
fi tted correctly and not broken or otherwise damaged?
- Is the cable between the printhead and J40 on the CPU board fi tted
correctly and not broken or otherwise damaged?
• Dirty printhead.
- Is the printhead clean? Residue from label adhesive, thermal paper
topcoating, or preprint ink prevents the printhead from functioning
correctly. Clean the printhead as described in the User's Guide.
• Wrong type of direct thermal media.
- In case of direct thermal printing, verify that the media is intended
for direct thermal printing (not thermal transfer!) and of an approved
quality.
• Wrong type of thermal transfer ribbon.
- In case of thermal transfer printing, verify that the stock of ribbon is
of an approved quality.
• Transfer ribbon loaded incorrectly.
- Verify if the ribbon is laoded with the ink-coated side facing the
receiving face material. If not, reload the ribbon as described in the
User's Guide.
• Transfer ribbon mechanism failure.
- See Chapter 15.13
• Wrong printhead voltage.
- Check that the printhead voltage +24VDC ±2V (see Chapter 13.4).
If the power on the CPU board is OK, but the trouble remains,
disconnect the power cable on the inner side of the printhead and use
probes to measure the voltage during printing between two adjacent
lines in the socket (see Chapter 12.4, connector P5 for schematics).