Intermec EasyCoder PF2i, PF4i, and PF4i Compact Industrial—Service Manual
Relay Out
The relays of the OUT ports 201–204 can be individually activated using
PORTOUT ON/OFF statements.
The status of the ports can be read by means of PORTIN functions. If a
relay is activated, PORTIN returns the value -1 (true), else it returns the
value 0 (false).
Max AC Load Breaking Capacity
Signal
Description
I
Current
Psw AC
Switching power
Usw AC
Switching voltage
Max DC Load Breaking Capacity
b
1
0.5
0.1
10
20
30
a: resistive load
b: inductive load L/R=20 ms
Connector Configuration
Pin Signal Name
Description
16
REL1nc
Relay 1 Normally Closed
1
REL1no
Relay 1 Normally Open
31
REL1com
Relay 1 Common
17
REL2nc
Relay 2 Normally Closed
2
REL2no
Relay 2 Normally Open
32
REL2com
Relay 2 Common
18
REL3nc
Relay 3 Normally Closed
3
REL3no
Relay 3 Normally Open
33
REL3com
Relay 3 Common
19
REL4nc
Relay 4 Normally Closed
4
REL4no
Relay 4 Normally Open
34
REL4com
Relay 4 Common
VCC
Simplifi ed schematics of a relay OUT port.
Max.
1A
100VA AC
100V AC
a
40 50
100
DC Voltage (VDC)
Chapter 14—Interfaces
Fingerprint Ref. No.
201
202
203
204
REL no
REL nc
REL com
177