Sony SRW-5000 Operation Manual page 81

Hide thumbs Also See for SRW-5000:
Table of Contents

Advertisement

Press the cursor center button. Each press of the button
alternately links and unlinks the cursor B.
2
Press the ENTRY button.
When the cursor buttons are aligned with the IN point,
and the IN point is at the OUT point, when you press
the ENTRY button at the OUT point, the time code is
either entered as a new value or updated. To update the
data, the winding diameter measurement must be
completed, and the drum locked, and then the tape
information read in.
Note
If the cursor (B) is not on the screen when the ENTRY
button is pressed, the time data on the line currently
specified by the cursor (B) changes to the current time
data, and the line is automatically displayed.
To clear the data
With the cursor buttons, align the cursor with the data you
want to clear, and in the case of the IN point hold down the
IN button, and in the case of the OUT point hold down the
OUT button, and press the CLR button, to clear the data.
You can also clear the data by holding down the CLR
button, and pressing the IN button or OUT button.
Effect on other data of data entry or update
When you enter or update the IN point or OUT point, other
data is updated as shown in the following table.
IN point entry/update:
State of the already-entered
data
The already-entered OUT
point data and entered or
updated IN point data are in
the correct time sequence
The already-entered OUT
point data and entered or
updated IN point are not in
the correct time sequence
OUT point data has not been
entered
OUT point entry/update:
State of the already-entered
data
The already-entered IN point
data and entered or updated
OUT point data are in the
correct time sequence
The already-entered IN point
data and entered or updated
OUT point are not in the
correct time sequence
IN point
OUT point
Data is
Data is not
updated
updated
Data is
Data is
updated
deleted
Data is
Data is not
updated
updated
IN point
OUT point
Data is not
Data is
updated
updated
Data is not
Data is not
updated
updated
State of the already-entered
data
IN point data has not been
entered
Updating File Name data
To update File Name data, press the cursor t button
several times.
To update data
1
With the cursor buttons, align the cursor with the File
Name data you want to update.
To move the cursor with the numeric buttons
Enter a line number with the numeric buttons, and
press the [F9] (CUENUM POINT) button. The cursor
moves to the line number you entered.
2
Press the [F4] (CHANGE DATA) button.
3
With the cursor T or t button, select the character
to be entered.
4
Press the [F7] (SET LETTER) button or cursor center
button.
The selected character is entered.
5
Repeat steps 3 and 4, to enter the data.
A maximum of 15 characters can be entered.
Note
If the number of entered characters is too large, a
memory overflow may occur, and it may become
impossible to enter other cue point data. Press the [F8]
(TAPE INFO) button to check the free memory
capacity.
To enter a space
Press the [F5] (SPACE) button, then carry out entry.
If you make an error in entry
Press the [F6] (BACK SPACE) button, then carry out
entry.
Canceling and repeating the process
Press the [F9] (CANCEL) button, then carry out entry.
To change a character during the operation
Press the cursor R button, then move the cursor to the
comment frame. With the cursor T button or t
button, change the character insertion position.
6
Press the [F10] (SAVE/EXIT) button.
This returns to the original menu screen.
IN point
OUT point
Data is not
Data is
updated
updated
4-4 CUE Menu
81

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srw-5500

Table of Contents