Only one message will be displayed even if there are
multiple messages. The number of errors appears at the
lower right, and you can check the messages using the R
and r buttons.
A history of errors is kept in the error log menu.
For more information about warning messages, refer to
the Maintenance Manual.
Use the displayed warning information to eliminate the
cause of the warning.
Item number
Display
01
NO EXTERNAL REFERENCE
02
LOST LOCK
03
NO EXTERNAL REFERENCE ON
FC
04
HD & SD REF ASYNCHRONOUS
05
PLL UNLOCK ON FC
08
NO SDI INPUT
10
VITC NOT READ
11
AUDIO PLL UNLOCKED
14
NO PB RF SIGNAL
15
INCONSISTENT EMPHASIS
16
INCONSISTENT FORMAT OF META
DATA
17
PB FREQUENCY IS UNSUITABLE
19
NO A1/A2 INPUT
1A
NO A3/A4 INPUT
1B
NO A5/A6 INPUT
1C
NO A7/A8 INPUT
1D
NO A9/A10 INPUT
For more information about eliminating the cause of
warning, refer to the Maintenance Manual.
To automatically display a warning message
Whenever a warning occurs, change the setting of the VTR
SETUP menu item 120 "WARNING DISPLAY" to "on".
To clear a warning message
To cancel the display of a warning message, see "Clearing
warning messages" on page 147.
S T A N D B Y O F F
P B / E E
R E C I N H
o f f
A S S E M -
B L E
o f f
I N S
T C
o f f
I N S
I N S
INS
V I D E O
CUE
A U D I O
o f f
off
Warning mark
Warning message
Meaning
There is no reference signal on the selected REF. INPUT
connector. The VTR is using an internal reference signal.
Capstan servo lock was lost during playback, recording, or editing.
When the VTR SETUP menu item A05 "PD EXT SD REF LOCK
MODE" is set to "lock1" or "lock2", no external SD reference signal
is input.
When the VTR SETUP menu item A05 "PD EXT SD REF LOCK
MODE" in is set to "lock1" or "lock2", HD reference signal and
external SD reference signal are not synchronized.
The PLL of the HKSR-5001 is not locked on the reference signal.
An SDI input signal cannot be detected.
VITC cannot be correctly read from the tape.
Audio lock generator PLL not locked to the video reference signal.
Playback heads cannot correctly read digital data from the tape.
Emphasis information on the tape is inconsistent with the system
emphasis status.
The meta data being input and the meta data recorded on the tape
have different formats.
The cassette is ejected automatically in line with the setting of the
VTR SETUP menu item 018 "AUTO EJECT LEVEL" because the
system frequency of the VTR and the frequency of the signal
recorded on the tape do not match.
No carrier detected on digital audio input on channels 1 and 2
No carrier detected on digital audio input on channels 3 and 4
No carrier detected on digital audio input on channels 5 and 6.
No carrier detected on digital audio input on channels 7 and 8.
No carrier detected on digital audio input on channels 9 and 10.