Inspection; 5-1.Measuring Instruments And Jigs Used For Inspection; 5-2.Connection Of Measuring Instruments For Inspection; 5-3.Inspection And Settings At Shipment - FujiFilm FinePix S2 Pro Service Manual

Hide thumbs Also See for FinePix S2 Pro:
Table of Contents

Advertisement

5. Inspection

5.Inspection
5-1. Measuring Instruments and Jigs Used for Inspection
Measuring instrument
TV monitor
Power supply
Pattern box
Waveform monitor
Digital voltmeter
Luminance meter
Color thermometer
Ammeter
Replacement Lens for Inspection
Power cable jig
Grey chart
LB140 filter
High-resolution chart
5-2. Connection of Measuring Instruments for Inspection
FinePix S2 Pro
CR123A x 2
5-3. Inspection and Settings at Shipment
<Step 1>
Item
Mode
Visual check
------
60
Remarks
NTSC TV monitor, minimum resolution 600 lines
AC adapter (eg AC-5VH), stabilized power supply
PTB450 or equivalent
LEADER: 5870 or equivalent
For general use
LS-110 (Minolta) or equivalent
Color Meter IIIF (Minolta) or equivalent
For general use (able to measure up to 1mA)
Common with adjustment jig: ZJ00396-100
Common with adjustment jig: ZJ00213-100
Common with adjustment jig: ZJ00254-100
Common with adjustment jig: ZJ00006-100
Common with FinePixS1Pro, FinePix4700Z: ZJ00398-100
IEEE1394CABLE
VIDEO OUT
Ammeter
Stabilizing supply, AC-5VH
Preparations for adjustment
and measurement
Visual check of camera.
FinePix S2 Pro (U/E) SERVICE MANUAL
Waveform
TV monitor
monitor
Adjustment and measurement
method
• No significant dents in body.
• Click sound of all switches, and
operation of sliders, normal.
• No significant foreign matter, or
cloudiness, in viewfinder.
• Flash mechanism opens and
closes smoothly.
Personal computer
OS:Windows Me
Measuring
Measurement
instrument
point
------
------

Hide quick links:

Advertisement

Table of Contents
loading