FinePix S2 Pro (U/E) SERVICE MANUAL
4-3. Measuring Instruments Used
Measuring instrument
Stabilized power supply
Pattern box
Waveform monitor
Digital voltmeter
Personal computer
Luminance meter
Color thermometer
TV monitor
Flash meter
4-4. Jigs Used
Productname / type name
FilterLB140
AF solid chart
AF Adjustment Lens
Gray Chart(Reflective type)
CCD defect data
USB cable
IEEE1394 cable
Hyper Utility Software HS-S2
Lens for inspection
Lens for adjustment
Power cable jig
FinePix S2 Pro PC adjustment soft
Standard Drive(microdrive)
DSC jig driver setup
Resolution Chart for High-Definition
* Download Jig of the bold-faced type from the server.
Remarks
For adjustment
PTB450 or equivalent
For function checks
For adjustment
For various adjustments and operational checks (PC-AT compatible, Windows Me).
LS-110 (Minolta) or equivalent
Color Meter IIIF (Minolta) or equivalent
NTSC TV monitor, minimum resolution 600 lines (for function checks).
For function checks
Pats.No
Use
ZJ00006-100
Camera System adjustments
ZJ00553-100
AF adjustment
J18266
AF adjustment
ZJ00254-100
Flash adjustmen
ZJ00556-100
CCD defect data
FZ04205-100
System adjustment
FZ04797-100
AF adjustment
ZJ00555-100
AF adjustment
ZJ00396-100
Inspection
------------
Image sensor Adjustment
ZJ00213-100
General Adjustment
ZJ00558-100
For PC adjustment
ZJ00397-100
Inspection
ZJ00476-100
For PC setup
ZJ00398-100
For Definition inspection
4. Adjustment
Remarks
Common with the DS-30/DS-20/DS-7
Only FinePix S2 Pro
Only FinePix S2 Pro
Common with the MX700/MX500
Only FinePix S2 Pro
Only FinePix S2 Pro
Common with the FinePix6800Z
Only FinePix S2 Pro
FinePix S1 Pro and commonness
FinePix S1 Pro and commonness
29