C. Vent Components Diagrams (continued)
Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (3,8 cm). The heat shield is designed to be
used on a wall 4 in. to 7-1/4 in. (10,2 cm to 18,4 cm) thick. If wall thickness is less than 4 in. (10,2 cm) the
existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (18,4 cm) a DVP-HSM-B
will be required.
15-1/8 in.
(38,4 cm)
(30,5 cm)
DVP-TRAP2
Horizontal Termination Cap
Figure 16.3 DVP vent components
8 in.
(20,3 cm)
12 in.
1 in.
(2,5 cm)
14 in.
(35,6 cm)
Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14
Heat
Shield
Term Cap
Trap2
Max
Effective
Length
DVP-TRAP2
7-1/4 in.
(18,4 cm)
3/8 in. (1,0 cm)
1 in. (2,5 cm)
7-3/4 in. to 10-3/8 in.
(19,7 cm to 26,4 cm)
DVP-FBHT
FireBrickTermination Cap
Minimum
Maximum
Effective Length
Effective Length
5-3/8 in.
9-3/8 in.
13,7 cm
23,8 cm
73