LS1900 Series Product Reference Guide
Rule Belongs To Set
Select the set a rule belongs to. (There are four possible rule sets.)
Actions
Select how to format the data for transmission.
Send Data
Send all data that remains, send all data up to a specific character selected from the
Alphanumeric
Keyboard, or send the next N characters. N = any number from 1 to 254,
selected from the
Alphanumeric
Setup Field(s)
Define fields as follows:
Move Cursor To a Character
Scan the MOVE CURSOR TO CHARACTER bar code on page 5-26, then any printable
ASCII character from the
the position after the matching character. If the character is not there, the rule fails and ADF
tries the next rule.
Move Cursor to Start of Data
Scan this bar code to move cursor to the beginning of the data.
Move Cursor Past a Character
This parameter moves the cursor past all sequential occurrences of a selected character.
For example, if the selected character is 'A', then the cursor moves past 'A', 'AA', 'AAA', etc.
Scan the MOVE CURSOR PAST CHARACTER bar code on page 5-26, then select a
character from the
Alphanumeric
not move (i.e., has no effect).
Skip Ahead "N" Characters
Scan one of these bar codes to select the number of positions ahead you wish to move the
cursor.
5-4
Keyboard.
Alphanumeric
Keyboard. When this is used, the cursor moves to
Keyboard. If the character is not there, the cursor does