Download Print this page

Device Information; Performance Data - Dimplex WI 40CS Installation And Operating Instrictions

Water-to-water heat pump for indoor installation

Advertisement

Available languages

Available languages

12

12 Device Information

1
Type and order code
2
Design
2.1
Degree of protection according to EN 60 529
2.2
Installation Location
3

Performance data

3.1
Operating temperature limits:
Heating water flow
Cold water (heat source)
3.2
Temperature spread of heating waterat W10 / W35
3.3
Heat output / COP
3.4
Sound power level
3.5
Heating water flow with an internal pressure differential of m³/h / Pa
3.6
Cold water flow rate at an internal pressure differential of
(heat source)
3.7
Refrigerant; total filling weight
3.8
Lubricant; total filling weight
4
Dimensions, connections and weight
4.1
Device dimensions without connections
4.2
Device connections to heating system
4.3
Device connections to heat source
4.4
Weight of the transportable unit(s) incl. packing
5
Electrical Connection
5.1
Nominal voltage; fuse protection
5.2
Nominal power consumption
5.3
Starting current with soft starter
Nominal current W10 W35 / cos ϕ 5)
5.4
5.5
max. power consumption of compressor protection
(per compressor)
6
Complies with the European safety regulations
7
Additional model features
7.1
Water in device protected against freezing
7.2
Performance levels
7.3
Controller internal/external
1. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, both the bivalence point and the regulation should
also be taken into consideration. The specified values, e.g. W10 / W55, have the following meaning: Heat source temperature 10 °C and heating water flow temperature 55 °C.
2. Operation with 2 compressors
3. Operation with 1 compressors
4. Note that additional space is required for pipe connections, operation and maintenance.
5. See CE declaration of conformity
6. The heat circulating pump and the heat pump controller must always be ready for operation.
E-10
°C
° C
K
1
at W7 / W55
kW / ---
kW / ---
1
at W10 / W50
kW / ---
kW / ---
1
at W10 / W35
kW / ---
kW / ---
dB(A)
m³/h / Pa
type / kg
type / litres
4
H x W x L mm
Inch
Inch
kg
V / A
1
W10 W35
kW
A
A / ---
W
6
WI 40CS
IP24
Indoors
Up to 55
+7 to +25
10.8
2
18.1 / 3.0
3
38.6 / 3.2
2
20.6 / 3.8
3
43.0 / 4.0
2
23.4 / 5.9
3
44.4 / 5.7
59
3.5 / 14000
9.5 / 17500
R407C / 6.7
Polyolester (POE) / 3.54
830 x 1480 x 890
G 1 1/4'' external
G 1 1/2'' external
309
400 / 35
7.81
26
14.1 / 0.8
70
5
Yes
2
External
WI 90CS
IP24
Indoors
Up to 55
+7 to +25
9.9
40.3 / 3.2
80.1 / 3.2
45.8 / 4.0
88.1 / 3.8
49.8 / 5.9
91.2 / 5.4
70
8.0 / 13000
20.0 / 19000
R407C / 15.0
Polyolester (POE) / 8.2
830 x 1480 x 890
G 2'' external
G 2'' external
460
400 / 63
16.97
60
30.7 / 0.8
70
5
Yes
2
External

Advertisement

loading

This manual is also suitable for:

Wi 90cs