Installation

!
Please note
Incorrect installation can lead to collector damage.
Use only gunmetal and brass fittings and copper pipes for the installa-
tion.
Use hemp only in conjunction with pressure and temperature resistant
sealants (e.g. Viscotex Solarpaste from Locher, CH-9450 Altstätten).
Never step onto solar panels.
Never solder near or on the collector.
A Collector
B Solar-Divicon
C Collecting tank
D Expansion vessel
E Pre-cooling vessel
F Shut-off valve
G Filling
H Manual solar fill pump
K Fill valve (F, G, H)
L Drain