BOILER DIMENSIONS
FRONT VIEW
All GG and GX(H)
GG-75H GG-100H GG-125H GG-150H GG-175H GG-200H GG-225H GG-250H GG-275H GG-300
A
19
3
19
3
19
4
4
B
13
1
13
1
13
4
4
C
5
6
6
D
46
53
53
3
1
8
4
E
6
13
13
3
4
F
8
8
8
G
1
1
1
1
1
4
4
H
1
1
1
1
1
2
2
J
2
3
2
3
2
4
4
K
9
9
9
1
1
4
4
GX, GXH AND GXHA SERIES STEAM AND HOT WATER BOILERS - DIMENSIONS IN INCHES
GXHA-100 GXH-105 GXHA-120 GXH-125
A
23
B
16
1
16
1
16
2
2
C
5
5
5
D
46
3
8
3
E
6
4
F
10
9
3
10
4
1
G
1
4
H
2
1
2
1
J
3
2
K
9
3
4
1
L
2
M
28
5
28
8
ORIFICE SIZES indicated for Sea Level are factory installed in
boiler unless otherwise specified by the local authority.
See VII, page 12 for burner input adjustment.
GAS VALVE CONNECTION Size is 1/2" f.p.t. for all sizes up to and
including GG-225 and GX-225. Larger boilers, gas valves may be 3/4" or
1/2" depending upon configuration (natural, L.P., standing pilot, IID).
COMBUSTIBLE FLOOR KIT increases all height dimensions by 1".
RAISED SLAB - When mounting boiler on a raised slab, the slab
must extend at least 2" beyond the boiler cabinet on all sides.
CHIMNEY HEIGHT: 15 ft. minimum from draft hood skirt to top of
chimney. CHIMNEY INSIDE DIAMETER must be same as Dimen-
sion "C" or larger. Larger diameter and/or height may be required if
two or more boilers or a boiler and another appliance are vented to
a single chimney.
RIGHT SIDE
GG / GX(H)-PT
GG SERIES HOT WATER BOILERS - DIMENSIONS IN INCHES
3
23
23
26
1
4
2
1
16
1
16
1
20
4
2
2
6
6
7
53
53
57
1
1
1
1
4
4
4
2
13
13
16
9
3
9
3
11
1
4
4
4
1
1
1
1
1
1
1
4
4
4
4
1
1
1
1
1
1
1
2
2
2
2
3
2
3
2
3
2
3
4
4
4
4
9
9
9
1
1
1
1
4
4
4
4
GXH-150 GXHA-160 GXH-170
1
23
26
2
1
16
1
20
20
2
2
6
7
6
53
1
55
1
4
2
13
14
9
3
11
1
11
3
4
4
4
1
1
1
1
4
4
2
1
2
1
2
2
1
1
3
3
2
2
9
3
9
3
4
4
1
1
2
2
5
28
5
8
8
RIGHT SIDE
GX(H)-PZT-PPZT
26
1
29
3
29
3
33
1
2
4
4
4
20
23
1
23
1
26
3
4
4
4
7
8
8
8
57
59
59
59
1
5
5
5
2
8
8
8
16
17
17
17
11
1
13
13
14
3
4
4
1
1
1
1
1
1
1
1
4
2
2
2
1
1
1
1
1
1
1
1
2
2
2
2
2
3
2
3
2
3
2
3
4
4
4
4
9
9
9
9
1
1
1
1
4
4
4
4
GXH-190 GXHA-200 GXH-210
1
1
3
26
26
29
2
2
4
20
20
23
1
23
1
4
4
7
7
7
7
55
1
55
1
55
1
2
2
2
14
14
14
11
1
11
1
13
1
11
1
4
4
2
4
1
1
1
1
1
1
4
2
2
2
1
2
1
2
1
2
2
2
1
1
1
3
3
3
2
2
2
9
3
9
3
9
3
4
4
4
1
1
3
2
2
4
28
5
8
Orifice
Size for
BOILER MODEL
GAS TYPE
Sea Level
GG/GX
Natural
42
Propane
54
Except GG-399H
Natural
40
GG-399H
Propane
53
GXH-105
Natural
44
through 275
Propane
54
Natural
43
GXH-300
Propane
54
GXH-300H
Natural
GG-350H
Gas*
43
Natural
45
GXHA
Propane
55
*For L.P. Propane gas, consult factory.
RIGHT SIDE
GX(H)-PZ
GG-325
GG-350
GG-350H GG-375H GG-399H
33
1
36
1
36
1
36
1
4
2
2
26
3
30
30
30
4
8
9
9
10
66
66
66
59
1
1
1
5
8
8
8
17
22
22
15
1
1
2
2
14
3
16
1
16
1
16
1
4
4
4
1
1
1
1
1
1
1
1
2
2
2
2
1
1
1
1
1
1
1
1
2
2
2
2
2
3
2
3
2
3
2
3
4
4
4
4
9
9
9
9
1
1
1
1
4
4
4
4
GX-225
GXH-230
GX-250
GXH-250 GXH-275 GXH-300H
3
3
3
1
29
29
29
32
4
4
4
23
1
23
1
23
1
26
4
4
4
8
7
8
7
56
5
55
1
56
5
55
1
8
2
8
14
14
14
14
13
13
13
14
3
1
1
1
1
1
1
1
1
2
2
2
2
1
2
1
2
1
2
1
2
2
2
1
1
1
1
3
3
3
3
2
2
2
9
3
9
3
9
3
9
3
4
4
4
3
3
3
3
4
4
4
4
GXHA Series
ORIFICE SIZES AT HIGH ALTITUDES
INCLUDES 4% INPUT REDUCTION FOR EACH 1000 FEET
ELEVATION–FEET
2,000
3,000
4,000
5,000
6,000
43
43
43
43
44
54
55
55
55
55
41
42
42
42
43
54
54
54
54
54
45
45
45
46
47
54
55
55
55
55
44
44
44
45
45
54
55
55
55
55
44
44
44
45
45
46
47
47
47
48
55
55
55
56
56
GALAXY
36
1
2
2
30
10
62
5
8
8
18
16
1
4
4
1
1
2
1
1
2
2
3
4
9
1
4
1
1
32
32
2
2
2
26
26
7
9
55
1
59
1
2
2
8
14
15
14
3
14
3
4
4
4
1
1
1
1
2
2
2
2
1
2
1
2
2
2
1
1
3
3
2
2
2
9
3
9
3
4
4
4
3
3
4
4
7,000
8,000
9,000
10,000
44
45
46
47
55
56
56
56
43
44
44
45
54
55
55
55
47
48
48
49
55
56
56
56
46
47
47
48
55
56
56
56
46
47
47
48
48
49
49
50
56
56
56
57

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents