2.2.2 Troubleshooting flow
(1)

List of troubles

No.
Remote controller display
1
None
Operates but does not cool.
2
None
Operates but does not heat.
3
None
Earth leakage breaker activated
4
None
Excessive noise/vibration (1/3)
5
None
Excessive noise/vibration (2/3)
6
None
Excessive noise/vibration (3/3)
7
None
Louver motor failure
8
None
Power supply system error (Power supply to indoor control PCB)
9
None
Power supply system error (Power supply to remote controller)
10
INSPECT I/U
INSPECT I/U (When 1 or 2 remote controllers are connected)
11
INSPECT I/U
INSPECT I/U (Connection of 3 units or more remote controllers)
WAIT
12
Communication error at initial operation
13
14
15
16
17
18
19
20
E16
21
E19
22
E28
23
E35
Cooling overload operation
24
25
E37
26
E38
27
E39
28
E42
29
E45
Outdoor sub PCB communication error
30
E47
Active filter voltage error
31
32
E51
Power transistor anomaly
33
E53
Suction pipe temperature error
34
E57
Insufficient refrigerant amount or detection of service valve closure
35
E58
Current safe stop
36
E59
Compressor startup failure
37
E60
Anomalous compressor rotor lock
Description of trouble
75
-
-
'10 • SCM-SM-094
Reference page
76
77
78
79
80
81
82
83
84
85
86
87~89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105, 106
107
108
109
110
111
112
113
114
115

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents