When installing the Filter Board Unit, make sure to observe the following
C A U T I O N
points.
• The black cable must cross over the white cable.
• The fuse holder must not contact with the cable
Before installing the Lamp Duct, attach the BS sheets to the Lamp Duct. Make
sure to align the sheets' corners with the corners indicated by the red lines in
the figure (within an error of ± 1 mm).
SEIKO EPSON
Fuse holder
Filter Board Unit
Figure 4-62.
Lamp Duct
Figure 4-63.