EMP-1825/EMP-1815/EMP-1810
10.Press the [QuickSetup] button once.
• The calibration at the Center position starts.
• When the calibration has been successfully finished, the image changes to a big "T (rep-
resenting "Tele") automatically. [Pause Window 3]
• If the Zoom Ring is not set to the Center position, the image returns to the "C" (Pause
Window 2) automatically.
• If this calibration has been failed, the [Unsuccessful Termination] window is displayed.
(refer to
[Unsuccessful Termination] window (p.
11.Adjust the Zoom Ring manually to the Tele side to the end.
12.Adjust the focus of the projected image with the Focus Ring.
13.Press the [QuickSetup] button once.
• The calibration at the Tele position starts.
• When the calibration has been successfully finished, the [Successful Finish] window is
displayed.
• If the Zoom Ring is not set to the Tele position, the image returns to the "T" (Pause Win-
dow 3) automatically.
• If this calibration has been failed, the [Unsuccessful Termination] window is displayed.
[Successful Finish] window
A beep sounds and a blue image with "No siganal" message is displayed.
• Press any button to finish the calibration. (No change on the projected image.)
[Unsuccessful Termination] window
Three beeps sound and a red image with "No signal" message is displayed.
• Press any button to quit the calibration. ([Unsuccessful Termination] window is cleared.)
C A U T I O N
If the calibration fails, go back to the Step 3 and make adjustment once again.
The case that the setting environment has a problem is also presumed, check
the environment again, too.
In the case of [Unsuccessful Termination] or canceling, the successfully
finished data before quitting are stored.
SEIKO EPSON
Figure 5-6. Pause Window 3
7))
5-7
CONFIDENTIAL
Revision:C