6.1.2 Initializing (Resetting) the AS Menu Values

The operational procedures and the values of initialization of the AS Menu are shown below.
Type
Operation
Item
Total Operation Time
Lamp Operation Time
(C/H/M/L)
Lamp ON
Lamp OFF
Lamp Replacement
Cool Down Complete
Error Log
Error Count
Control
SEIKO EPSON
Contents
Internal overheat
Fan error
Thermistor error
Lamp burnt out
Lighting failure
Internal error (RAM)
Internal error (ROM)
Internal error (I2S)
Internal error (DR)
Lamp cover open
Connection failure to Electrical double
layer capacitor
Cinema Filter error
Auto IRIS error
Sub system ROM error
Sub system error (PW error)
Thermal data of each thermistor
Voltage of each fan
Clearing the Lamp
Information
Press
and
[Up]
[Source]
for 10 sec. during
displaying Page 1/Page 2.
No Change
Reset to 0H
Reset to 1
Reset to 0
Add 1 to the
current value
Reset to 0
No Change
No Change
No Change
2-digit number (00-99)
Over 99: "99"
(Not cleared to "0.")
Acquired data of TEMP? of the
ESC/VP21 command
Acquired data of TEMP? of the
ESC/VP21 command
Clearing the AS
Information
Press
and
[Down]
for 10 sec.
[Source]
during displaying Page 1/
Page 2.
Reset to 0H
Reset to 0H
Reset to 1
Reset to 0
Reset to 0
Reset to 0
No Change
No Change
No Change
6-5
CONFIDENTIAL
Representation
Clearing the Log
Information
Press
for more
[Right]
than 5 sec., then within 3
sec. press
for 2
[Select]
sec. during displaying
Page 2.
No Change
No Change
No Change
No Change
No Change
No Change
Spacing
(Status of acquiring none)
Reset to 0
No change
Revision:C