CFX VENT FREE FIREPLACE SYSTEM
MILLIVOLT CONTROL LIGHTING INSTRUCTIONS
1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo
igniter does not light the pilot, Refer to the instructions for Match Lighting Instructions, Page 25.
4. Turn gas control knob clockwise
ON/OFF switch to OFF position.
5. Wait (5) minutes to clear out any gas. Then smell for gas, including near the fl oor. If you smell gas,
STOP! Follow "B" in the safety information label. If you don't smell gas, go to next step.
6. From OFF position, turn the gas control knob counterclockwise
knob for 5 seconds.
7. With the control knob pushed in, push in and release the piezo igniter button to light the pilot.
8. Continue pushing the control knob in for a further 60 seconds to prevent the fl ame detector from shut-
ting off the gas while the probe is warming up. Release the control knob.
9. Turn gas control knob counterclockwise
10. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to
ON position or adjust thermostat to desired setting.
11. If the gas logs will not operate, follow the instructions To Turn Off Gas To Appliance below and call
your service technician or gas supplier.
WARNING: Wait 30 seconds before readjusting the heater when the control knob has
been turned down to a lower setting.
Pilot
1. Turn control knob clockwise
2. If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.
3. If applicable: Turn off all electric power to the heater.
22
to the OFF position, set the thermostat to the lowest setting and turn
Control Knobs
TO TURN OFF GAS TO HEATER
to OFF position to completely shut off the heater.
to the ON position.
OPERATING INSTRUCTIONS
to IGN position. Push in control
Piezo
20301726