For Fireplaces equipped with American Flame Automatic Control System (IN or IP)
Warning:
A. This fireplace is equipped with an ignition device
which automatically lights the pilot and main burner.
The pilot and burner light automatically with the hand
held remote control only. DO NOT try to light the
pilot by hand. Before lighting this appliance, follow
these instructions exactly.
B. BEFORE OPERATING, smell all around the
appliance area for gas. Be sure to smell next to
the floor because some gas is heavier than the air
and will settle on the floor.
What to do if you smell gas
• Do not try to light any appliance.
1. STOP! Read the safety information above before
continuing.
2. Turn off all electrical power to the appliance.
3. This appliance is equipped with an ignition device
which automatically lights the pilot. DO NOT try to
light the pilot by hand.
4. Turn the wireless remote OFF.
5. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP. Follow instruction B
in the safety warnings above. If you do not
smell gas, go on to the next step.
6. Turn ON all electrical power to the
appliance.
7. Turn wireless remote ON.
9. If the appliance will not operate, follow the
instructions TURNING OFF THE GAS TO
THE APPLIANCE, and call your service
technician or gas supplier.
1. Turn the wireless remote to the OFF position.
2. Turn OFF all electrical power to the fireplace if
service is required.
3. Turn the shut-off valve on the gas supply line to
the OFF position.
20011956
Lighting & Operating Instructions
If you do not follow these instructions exactly, a fire or explosion may
result, causing property damage, personal injury and loss of life.
For Your Safety, Read the Following Warnings
before Lighting the Appliance
Lighting Instructions
Turning Off the Gas to the Appliance
• Do not operate any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppliers
instructions.
• If you cannot contact your gas supplier call the
Fire Department
C. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and replace any part of the
control system and any gas control that has been
under water.
"S" Connection
Connect to Module
Pilot Gas
Black Plastic Cap
Connection Side or Back
Pilot
Adjustment
Motor Wires
Screw
Pilot Internal Solenoid
Connection
Orange & White Wires
������
������ �����
����
1/2" Gas Supply
Chateau™
Spark to Pilot
Pilot Assembly
Motor Drive
Minimum Rate
Screw
Main Valve Internal Solenoid
Connection
Green & White Wires
1/2" NPT X 1/2" Flare
Shut-off Valve
1/2" Gas Tight or
Tinned Copper
(from valve)
(Not provided)
FP297A
INSTA VENT FREE
UVHB26 GAS SUPPLY
7/1/98
"I" Connection
Connect to
Module
FP297A