CFX VENT FREE FIREPLACE SYSTEM
ELECTRICAL WIRING
The millivolt valve is a self-powered combination gas
control that DOES NOT REQUIRE 110V AC TO OPERATE.
Field Installed
Wall Switch
or Remote
Receiver
On/Off
Switch
Figure 19 -
Wiring Diagram
Label all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation. Verify
proper operation after servicing.
16
TH = 3
TP = 1
TP/TH = 2
On/Off
Switch
ODS Pilot
Millivolt Valve
Switch
CONNECTING OPTIONAL WALL SWITCH
OR THERMOSTAT
1. Use 18 AWG, two-wire cable, 20 feet maximum length.
2. At one end of the cable, connect both wires to the wall
switch or thermostat. At the other end, connect one wire
to TP/TH and one wire to TH. The color of the wires
does not matter.
ELECTRICAL CONNECTIONS
ODS Pilot
Spade Terminal
FP2112
20301726