6. Adjustment

6-1. Items to adjust

The table 6.1.1 shows the adjustment required when parts are replaced. The items with ○ are the subjects to
adjust.
Item to adjust
CCD2CH adjustment
(CCD2CH)
CCD sensitivity
(SENSITIVE)
IRIS/ND
Shutter
CCD defect pixel
White balance
Zoom/focus
HDD format
Firmware update
Factory setting
Notes:
1) Only required items should be adjusted. The adjustment should be performed sequentially from the top of
the table. The proper adjustment results may not be given unless specified order is followed.
2) Update the firmware only when the versions is different.
3) All items will be reset to the default values when the factory setting is applied.
4) The contents of HDD will not be erased by the adjustment.

6-2. Devise to Use

- Standard light source
Model name:
LSB-6M/10
Manufacturer:
Tsubosaka Electric Co., Ltd.
For CCD2CH adjustment and white balance purpose.
- Collimator
Model name:
VC-1100
Manufacturer:
Kyoritsu Electric Co., Ltd.
For zooming/focus adjustment purpose.
- Power supply (AC adapter, accessories)
- Lens hood
Model name:
MEHLH1 (attached to MEHV10)
- SD card
Capacity:
8MB or greater
- Adjustment firmware *
File name:
ADJR20.bin (provided by Toshiba)
- Firmware for update *
File name:
GSCR20.bin and UP_R20.bin (provided by Toshiba)
Table 6.1.1
Lens Module ASSY
(HA52)
-
Parts name (parts number)
MAIN PCB ASSY
(U001)
-
41
HDD ASSY
(HA5A)
-
-
-
-
-
-
-